Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

Properties of an openUTM-LU62 Gateway

The following table contains all the properties of an openUTM-LU62 Gateway.

The meanings and values permitted for the various properties can be found in the Management Console online help system under Managing BeanConnect proxy components - Managing openUTM-LU62 Gateways -openUTM-LU62 Gateway, table columns and openUTM-LU62 Gateway instance, Properties.

Keyword (key)
in MC-CLI
1

Field name in the GUI 1

Funct. 1

Property value 1

admin-port

MC-CmdHandler
Listener Port

cm / g / ma)

(String numeric)

admin-pw

MC-CmdHandler
User Password

cm / ma)

(String)

admin-
state

Administrable

g

BcDef.ACTION_RESULT_ ADMINISTRABLE
or BcDef.ACTION_RESULT_ NOT_ADMINISTRABLE2

desc

Description

g / mb)

(String)

host

Host

cm / g / ma)c)

(String)

install-
path

Installation Path

cm / g / m

(String)

install-
path-cs

Installation Path
(Communication Service)

c / g / mf)

(String)

name

Name

gd)

(String)

op system

Operating System

gb)

(String)

proxies

Proxies

ge)

(String)

trave-level

Trace Level

cd / g / mb)

BcDef.LOGGING_MODE_xxx with xxx = OFF/1/2/32

xaptp-trace

XAP-TP Trace

cd / g / mb)

BcDef.LOGGING_MODE_xxx with xxx = ON/OFF2

1 For the meanings of the columns and abbreviations, see Properties

2 The possible values of xxx can be found in the JavaDoc (Java class BcDef) in the JavaDoc subdirectory of the Management Console installation directory

Notes on the indices a) to f) in the table:

a)

If one of the properties hostadmin-port or admin-pw is specified during a create or modify operation, the associated MC CmdHandler is searched for or created internally and is assigned to the openUTM-LU62 Gateway. The MC CmdHandler must be available as otherwise the call is rejected. In the case of a local host, it is not necessary to specify admin-port and admin-pw.

b)

If the MC-CmdHandler is not available, the value BcDef.VALUE_UNKNOWN (="<.>") is output for these properties in getProperties().

c)

The property host can only be changed if the host is the same. (i.e. modifiable but will generally be rejected).

d)

The name is generic and consists of the host name and the installation path: "<host> [<install-path>]"

e)

The proxies (with name and object) can also be read using the function getProxies(). In this case, the names are sent as a comma-separated string. Note: If the proxy names contain commas then it is possible that the returned information may be ambiguous.

f)

The property install-path-cs should be specified when creating an openUTM-LU62 Gateway, because errors may occur when administering the openUTM-LU62 Gateway if there is no link to a communication service. If no communication service has as yet been configured under the specified path, a new object is generated. Some of the values that this contains are dummy values that must be adapted in order to use the communication services. If the property is not specified, an already configured communication service is searched for on the host on which the openUTM-LU62 Gateway is located and is assigned to the openUTM-LU62 Gateway.