Remove changeover time
Component: | BS2000 |
Functional area: | System control and optimization |
Domain: | SYSTEM-MANAGEMENT |
Privileges: | TSOS |
Function
The REMOVE-CHANGE-DATE command removes the latest future changeover time from standard daylight time to daylight saving time (or vice versa).
The changeover time to be removed may not be within the next hour or the next hour but one. If it is in the next hour but one, it can be changed using the MODIFY-CHANGE-DATE command.
Format
REMOVE-CHANGE-DATE |
DATE = *LATEST |
Operands
DATE = *LATEST
The latest future changeover time is to be removed.
Return codes
(SC2) | SC1 | Maincode | Meaning |
---|---|---|---|
0 | CMD0001 | Command executed | |
1 | CHD0010 | Syntax error in the command | |
32 | CMD0221 | System error in the command | |
64 | CHD0011 | Semantic error in the command |