Clear down RFA connection and terminate partner task
Component: | RFA |
Functional area: | Pubset and MRSCAT management |
Domain: | MULTI-CATALOG-AND-PUBSET-MGMT |
Privileges: | STD-PROCESSING |
This command is available only to users who have the RFA software product (see also the “RFA” manual [31]).
Function
The command REMOVE-RFA-CONNECTION clears down one or all RFA connections previously set up with the SET-RFA-CONNECTION command. When the last RFA connection to a remote processor is cleared down, the partner task on the remote processor is simultaneously terminated.
When the local user task is terminated (EXIT-JOB or LOGOFF), the system automatically clears down all RFA connections set up during the current task.
The REMOVE-RFA-CONNECTION command is rejected if a program is loaded.
The user can issue the SHOW-RFA-CONNECTIONS command to get information on still existing RFA connections.
Note
More than one SET-RFA-CONNECTION command can be issued for a single catalog ID. The same number of REMOVE-RFA-CONNECTION commands must be issued to clear down a connection as SET-RFA-CONNECTION commands were issued.
Format
REMOVE-RFA-CONNECTION |
CATALOG-ID = <cat-id 1..4> / *ALL |
Operands
CATALOG-ID = <cat-id 1..4> / *ALL
Catalog ID to which the RFA connection is to be cleared down. Specifying *ALL lets all RFA connections be cleared.
Return codes
(SC2) | SC1 | Maincode | Meaning |
---|---|---|---|
0 | RFA0002 | Command executed | |
1 | 0 | RFA0002 | No RFA connection exists which can be cleared down |
64 | RFA0025 | Program loaded | |
64 | RFA0027 | Configuration error |