Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

REQUEST-MAIN-CONSOLE-FUNCTIONS

&pagelevel(3)&pagelevel

Request change of main operator terminal

Component:

BS2000

Functional area:

Operator terminal control

Domain:

not allocated

Privileges:

OPERATING

Routing code:

E

Function

This command allows operators to request that the operator terminal (console) on which the command is issued should be defined as the main operator terminal (console). If the request is granted on the current main operator terminal ('Y' or 'YES' entered when message NBR1085 is issued there), the operator terminal is changed.

The command is allowed on physical operator terminals only.
Moreover, it must not be issued

  • from the current main operator terminal

  • from teleservice

Format

REQUEST-MAIN-CONSOLE-FUNCTIONS                                                                                                  

       

Return codes

(SC2)

SC1

Maincode

Meaning


0

CMD0001

Command successfully executed

1

0

NBR1081

Operator terminal is already main operator terminal. Command ignored


2

CMD0198

Shutdown in progress


64

CMD0216

User does not have required privilege


64

NBR0200

Function not yet unavailable


64

NBR1080

Command is reserved for physical operator terminals


64

NBR1082

Command rejected by main operator terminal


129

NBR1083

Command already being processed. Try again later


130

NBR1084

Command rejected owing to memory or task saturation

Results

If the command is issued at a console, the following message appears on the main console:

NBR1085 ALLOW '(&00)' TO BECOME THE MAIN CONSOLE? REPLY (Y=YES; N=NO)

(&00) stands for the console on which the command was issued. This is the console which is to become the new main console.
If the message is answered in the affirmative, console (&00) is made the new main console, as indicated by the message

EXC0655 '(&00)' BECOMES MAIN CONSOLE

If the message is answered in the negative (any response other than 'Y' or 'YES'), the existing main console retains its function. The requested change is rejected. The following message is displayed on the console which requested the change:

NBR1082 '/REQUEST-MAIN-CONSOLE-FUNCTIONS' REJECTED BY MAIN CONSOLE