The accounting record is written every time that the deinitialization phase of a subsystem is executed.
This termination routine traverses the subsystem under the control of DSSM on execution of the STOP-SUBSYSTEM and HOLD-SUBSYSTEM commands.
Maximum length of the subsystem termination accounting record: 54 bytes
(A) Record description: record identifier: “ESMD”
(B) Identification section: subsystem identification
(C) Basic information
Field no. | Displacement | Length (bytes) | Format | Meaning | |
hex. | dec. | ||||
1 | 00 | 0 | 1 | B | Status indicator 1 |
1There are two possible values for the status indicator:
1
subsystem is placed in the wait state (HOLD-SUBSYSTEM command)
0
subsystem is terminated (STOP-SUBSYSTEM command)
2“S” for summer time; “W” for winter time
Length of the basic information: 3 bytes
(D) Variable information
The variable information of the subsystem termination accounting record contains no record extension.