Selection 1 (Modify RU Attributes ...) enables you to modify the name and attributes of a release unit. The attributes of a release unit include the type of release unit, the mainversion number, the correction state, the functional level on which the release unit executes, and comments if applicable.
Any changes you make to the name and/or main version of a release unit in this mask are also implemented in the name of the SYSSII file you generate.
PROGRAM : IMON-SIC Modify Release Unit Attributes PANEL : MRUAT -------------------------------------------------------------------------------- Name : TESTPROG Main version : 01.0 Correction state : A00 Functional level : B (U/P/B) Comments : N (Y/N) Fill the attributes and press DUE -------------------------------------------------------------------------------- K1=cancel K2=interrupt K3=refresh --------------------------------------------------------------------------------
Figure 72: Modify release unit attributes
All fields in this mask are assigned preset values by IMON-SIC, however they can be changed.
Name | Enter the release unit name as <text 1..30 without-sep> (see "Installation unit (IU) "). |
Main version | The main version must be entered in the form <nn.n>, where n is a digit from 0 to 9. |
Correction state | Enter the correction state as a three-character code <aso> (a=A..Z, so=00..99). |
Functional Level | The functional level of the release unit. The options are: | |
U P B | Task Unprivileged, TU Task Privileged, TPR Both, if the release unit or parts of the release unit can be executed in both TU and TPR. | |
Comments | Comments can be specified if desired. The preset is N (No). Three lines with up to 70 characters each are allowed for each comment. |
The SYSSII menu reappears when you confirm the settings.