CMS settings
CMS buffer settings can be made with the RESIDENT-BUFFERS and NUMBER-OF-BUFFERS operands of the ADD-/MODIFY-MASTER-CATALOG-ENTRY or IMPORT-PUBSET command. These specifications are evaluated when the pubset is imported (IMPORT-PUBSET command), according to the following hierarchy:
Explicit parameter specification in the IMPORT-PUBSET command
Specifications via the ADD or MODIFY-MASTER-CATALOG-ENTRY command. If only one of the RESIDENT-BUFFERS or NUMBER-OF-BUFFERS parameters is specified, the default value applies to the other (RESIDENT-BUFFERS=*NO, NUMBER-OF-BUFFERS=32).
Definitions according to system parameters CATBUFR and BMTNUM
Operating modes
The operating modes can be set with the ADD-/MODIFY-MASTER-CATALOG-ENTRY command using the following operands:
ACCESS-CONTROLLED: exclusive use by one user ID
SHARED-PUBSET: access by several systems (shared pubset)
The shared pubset property can also be defined when the pubset is imported (IMPORT-PUBSET command, USE operand).
Default settings for pubset space and file format
The default values for the size of primary, secondary and maximum allocation of files can be set for SM and SF pubsets (MODIFY-PUBSET-SPACE-DEFAULTS (EDIT-PUBSET-SPACE-DEFAULTS) command).
The command MODIFY-PUBSET-SPACE-DEFAULTS ...,PUBSET-TYPE=*S-M(FILE-FORMAT=*K/*NK2/*NK4) can be used for setting the file format default for SM pubsets.