Synchronization with the carrier system time on SU x86

&pagelevel(4)&pagelevel

On SU x86 the system time is automatically synchronized with the SVP clock, in other words with the time of the carrier system, if no other synchronization instance is present in BS2000. The carrier system receives the time of the Management Unit using NTP.

>

The corresponding information can be found in the SYSTEM-TIME-PARAMETER section of the SHOW-SYSTEM-INFORMATION command’s output: SYNCHRONIZATION=X2000.

The MU can be connected to an external timer. These external timers are visible in the BS2000 time only if their quality is retained through to the carrier system (i.e. the stratum of the NTP server in the carrier system is <= 4).

>