CATALOG exits (070/071)

&pagelevel(3)&pagelevel

Use of the following commands can be monitored at two exit points with an exit routine.

  • CREATE-FILE

  • CREATE-FILE-GENERATION

  • CREATE-FILE-GROUP

  • MODIFY-FILE-ATTRIBUTES

  • MODIFY-FILE-GENERATION-SUPPORT

  • MODIFY-FILE-GROUP-ATTRIBUTES.

In addition, it is possible to monitor the CATAL macro.

The request exit routine can reject or modify a CATALOG request.

The return exit routine can initiate the appropriate logging or recording actions after the execution of a CATALOG request.

Return exit (070)

The following information is passed to the exit routine:

R1 = A(EX070 exit parameter area)
R12 = A(TPR program manager)
R13 = A(save area of calling component)
R14 = A(indirect return)
R15 = A(exit routine)

The exit routine cannot send a return code to the system module. The return from the return exit routine is followed by the return from CATALOG processing. The exit routine must set the value X'0000' or X'0004' for the maincode in the standard header of the parameter area. If the maincode contains any other value, the following message appears on the console:

% DMS06B9 CALLING SYSTEM EXIT (&00) RESULTS IN ERROR CODE (&01)

Request exit (071)

The register settings are the same as for the return exit.

The return code for the calling system module is sent in the maincode of the standard header of the exit parameter area. The following values are possible:

X'0000'

CATALOG processing is performed with the CATALOG parameter area, which may have been modified by the exit routine.

X'0004'

The CATALOG request is rejected with error code X'0513'.
For commands, the following message is sent to SYSOUT:

DMS0513 USE OF SPECIFIED COMMAND OR 'CATAL' MACRO RESTRICTED BY 
SYSTEM ADMINISTRATOR. COMMAND OR MACRO REJECTED.

other

Same as for X'0004'; in addition the following message is displayed on the console:

DMS06B9 CALLING SYSTEM EXIT (&00) RESULTS IN ERROR CODE (&01)

Notes

  • Registers 12, 13 and 14 must not be destroyed by the exit routine.

  • The exit routine can set or modify the AUDIT parameter without the user having any means of influencing or preventing the change.

DSECT

         EX070 MF=D
         MFTST MF=D,PREFIX=D,MACID=MAX,ALIGN=F,                        C
               DMACID=MAX,SUPPORT=(D,C,L),DNAME=MAXMDL
DMAXMDL  DSECT ,
               *,##### PREFIX=D, MACID=MAX #####
*   Parameterarea
DMAXHDR  FHDR  MF=(C,DMAX),EQUATES=NO                   Standard-Header
DMAXHDR  DS    0A
DMAXFHE  DS    0XL8            0   GENERAL PARAMETER AREA HEADER
*
DMAXIFID DS    0A              0   INTERFACE IDENTIFIER
DMAXFCTU DS    AL2             0   FUNCTION UNIT NUMBER
*                                  BIT 15    HEADER FLAG BIT,
*                                  MUST BE RESET UNTIL FURTHER NOTICE
*                                  BIT 14-12 UNUSED, MUST BE RESET
*                                  BIT 11-0  REAL FUNCTION UNIT NUMBER
DMAXFCT  DS    AL1             2   FUNCTION NUMBER
DMAXFCTV DS    AL1             3   FUNCTION INTERFACE VERSION NUMBER
*
DMAXRET  DS    0A              4   GENERAL RETURN CODE
DMAXSRET DS    0AL2            4   SUB RETURN CODE
DMAXSR2  DS    AL1             4   SUB RETURN CODE 2
DMAXSR1  DS    AL1             5   SUB RETURN CODE 1
DMAXMRET DS    0AL2            6   MAIN RETURN CODE
DMAXMR2  DS    AL1             6   MAIN RETURN CODE 2
DMAXMR1  DS    AL1             7   MAIN RETURN CODE 1
DMAXFHL  EQU   8               8   GENERAL OPERAND LIST HEADER LENGTH
*
DMAXCRC  DS    F                         CATAL-Returncode
DMAXCPL  DS    A                         Addr der CATAL-PL
DMAX#    EQU   *-DMAXHDR

In the case of the return exit, the MAXCRC field contains the return code of CATAL processing

CATALOG parameter list

The DSECT for the CATALOG parameter area is generated by means of the CATAL macro:

[name] CATAL MF=D[,PREFIX=prefix/*],VERSION=3

The MAXCPL field of the exit parameter area contains a pointer to the CATALOG parameter area. The CATALOG parameter area must be generated in the format valid as of BS2000/OSD-BC V3.0 (VERSION=3).