A new software configuration is created, an already existing software configuration is overwritten. All settings previously found in this entry are lost. At the end, all the system loader definitions are checked. If a default setting is determined, the settings from the newly-entered software configuration are used instead.
Format
CREATE-SW-CONF |
NAME = 'swkonfname' [,PASS = 'password'] ,ADD = productversion / (productversion,...) [,SETTINGS = ( ,SHARE = NO / YES ,SAVE = NO / YES ,INSTALL = NO / YES ,INFORMATION = MAX / MED / MIN ,FUNCTION-NAME = NO / YES [,VOLUME = vol,DEVICE = dev] [,PATH = [:catid:][$userid.]filename] ,LOADER-FORMAT = SUB-SYSTEM / BS2000 )] [,ERROR = ON(<integer 0..31>) / OFF(<integer 0..31>)] |
Operands
NAME = 'swkonfname'
Name of the software configuration to be created.
PASS = 'password'
Password used to protect the software configuration.
ADD = productversion / (productversion, ...)
Product and, where applicable, product version to be added to the software configuration. The product name can be up to 15 characters long. The product version is to be entered in the format V[n]n.nn[nn].
SETTINGS =
Determines the loader attributes with respect to the software configuration. The first operand named can be entered without a leading comma; any order can be used.
SHARE = NO / YES
Defines access authorization.
SAVE = YES / NO
Backup of the system loader file which is overwritten at installation. System loader files in BS2LOADER format are always backed up.
INSTALL = YES / NO
Install under the installation path name.
INFORMATION = MED / MAX / MIN
If MAX is specified, the following information is output on the screen when the system loader is installed:
Name of the system loader and the generation version of the products in the loader, as well as the supply component version they used.
All correction numbers for notebook entries which were active at creation.
The system loader modifications carried out.
All activated OPT-REPs.
For information on the output for MIN/MED, see "Loader services".
FUNCTION-NAME = NO / YES
For the SUBNOs of the activated OPT-REPs, the function names are output. If NO is selected, only the PM numbers are output.
VOLUME = vol, DEVIVE = dev
Volume and device under which the corresponding loader is stored.
PATH = :catid:$userid.filename
Path name under which the corresponding loader is stored.
LOADER-FORMAT = SUB-SYSTEM / BS2000
BS2000 format required at system loading; the subsystem is processed by DSSM.
ERROR = ON(<integer 0..31>) / OFF(<integer 0..31>)
In the event of an error, the specified job switch is set (ON) or reset (OFF).