Output in X.25 address format

&pagelevel(5)&pagelevel

Example for the output of X.25 address parameters (Windows systems)

ftshwptn mchx25 -pa

NAME = mchx25

        TYPE = X.25 [FarSync] ID = 0
        DTE = 123456789012345

        NSAP = 4300000000012345678901

           AFI = 43
           IDI = 123

           DSP = 45678901

        CUD = 03010100
        CLASS = 2/2        WSIZE = 7             PSIZE = 4096

        CUG = 9999         THPUTCL = 192000      REVCHRG = NO

        IF = 0:0           SPARE-IF = 1:0,2:0

Example for the output of X.25 address parameters (Linux)

ftshwptn mchx25 -pa
NAME = mchx25
       TYPE = X.25 [FarSync] ID = 0
       DTE = 123456789012345
       NSAP = 4300000000012345678901
          AFI = 43
          IDI = 123
          DSP = 45678901
       CUD = 03010100
       CLASS = 2/2     WSIZE = 7         PSIZE = 4096
       CUG = 9999      THPUTCL = 192000  REVCHRG = NO
       IF = 0          SPARE-IF = 1,2

Explanation

NAME

Name of the partner list entry.

TYPE

Address type

X.25 [FarSync] X.25 address for the FarSync X.25 transport system.

TCP/IP IPv4 or IPv6 address for TCP/IP-RFC1006 transport system.

HOST/TNS Host or TNS name.

ID

Index of the address extension. Only used for diagnosis purposes.

DTE

DTE address of the partner system.

NSAP

NSAP address of the partner system. If the NSAP is specified as an OSI network address, then it is followed by the individual values for AFI, IDI and DSP.

AFI

Authority and format Identifier of the NSAP.

IDI

Initial domain identifier of the NSAP.

DSP

Domain-specific part of the NSAP.

CUD

User data for the X.25 connection setup.

CLASS

Transport protocol class.

WSIZE

Window size.

PSIZE

Packet size.

CUG

Closed user group.

THPUTCL

Throughput class.

REVCHRG

Reverse charging.

IF

Local line on the FarSync X.25 card that is used to set up the connection.

SPARE-IF

Alternative line and list with alternative lines on the FarSync X.25 card, via which a further connection setup is initiated as an alternative in case of a failed connection setup.