BCSET Setting diagnostic operands | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ERROR=...
ERROR controls the “error response” function.
ERROR= *unchanged
The previous setting remains unchanged.
ERROR=(ON,...)
An error response is switched on.
REASON=...
Specifies the reason why the error response – defined in the ACTION operand – is to be made.
The values can also be specified as a list (list-poss).
REASON= *none
No (additional) specification of the reason for the error response.
REASON=BS2-SS
The reason for the error response lies in the use of a BS2000 interface.
REASON=BOURSE-SS
The reason for the error response lies in the use of the BS2000 bourse interface.
REASON=TIMER-SS
The reason for the error response lies in the use of the BS2000 timer interface.
REASON=SIGNAL-SS
The reason for the error response lies in the use of the BS2000 signal interface.
REASON=CONTINGENCY-SS
The reason for the error response lies in the use of the BS2000 CONTINGENCY interface.
REASON=SLOTPOOL-SS
The reason for the error response lies in the use of the BS2000 slotpool interface.
REASON=TASK-SS
The reason for the error response lies in the use of the BS2000 task interface.
REASON=USER-TIMEOUT
The reason for the error response is a time-out while waiting for the user call to be processed under the BCAM task.
REASON=MEMORY-SS
The reason for the error response lies in the use of the BS2000 memory interface.
REASON=DEVICE-SS
The reason for the error response lies in the use of the BS2000 device interface.
ACTION=...
Defines the action to be taken in response to the errors specified with REASON.The values can also be specified as a list (list-poss).
ACTION= *none
No error response is triggered.
The values can also be specified as a list (list-poss).
ACTION=DUMP
A dump is created (in the event of an error return code).
ACTION=MSG
Message BCA0777 is generated (even if the return code is ok).
ERROR=(OFF,...)
An error response is switched off.
REASON=...
Specifies the reason for the error response defined in the ACTION operand. Apart from BS2-SS,USER-TIMEOUT, the remaining values can also be specified as a list (list-poss).
REASON=(BS2-SS,USER-TIMEOUT)
The reason for the error response lies in the use of a BS2000 interface or a time-out while waiting for the user call to be processed under the BCAM task.
REASON=BS2-SS
The reason for the error response lies in the use of a BS2000 interface.
REASON=BOURSE-SS
The reason for the error response lies in the use of the BS2000 bourse interface.
REASON=TIMER-SS
The reason for the error response lies in the use of the BS2000 timer interface.
REASON=SIGNAL-SS
The reason for the error response lies in the use of the BS2000 signal interface.
REASON=CONTINGENCY-SS
The reason for the error response lies in the use of the BS2000 CONTINGENCY interface.
REASON=SLOTPOOL-SS
The reason for the error response lies in the use of the BS2000 slotpool interface.
REASON=TASK-SS
The reason for the error response lies in the use of the BS2000 task interface.
REASON=USER-TIMEOUT
The reason for the error response is a time-out while waiting for the user call to be processed under the BCAM task.
REASON=MEMORY-SS
The reason for the error response lies in the use of the BS2000 memory interface .
REASON=DEVICE-SS
The reason for the error response lies in the use of the BS2000 device interface.
ACTION=...
Defines the action to be taken in response to the errors specified with REASON. Apart from MSG,DUMP, both values can also be specified as a list (list-poss).
ACTION=(MSG,DUMP)
All error responses are switched off.
ACTION=DUMP
No dump is created (in the event of an error return code).
ACTION=MSG
Message BCA0777 is not generated (even if the return code is ok).
CELL-DOUBLING=...
Controls the “check for cell-doubling” function.
CELL-DOUBLING= *unchanged
The setting for the function remains unchanged.
CELL-DOUBLING=ON
The “checking the use of cell-doubling” function is switched on, i.e. if cell-doubling is detected, a system crash is generated.
CELL-DOUBLING=OFF
The “checking the use of cell-doubling” function is switched off.
DISCON-RETARDING=...
Controls the “retarded transport connection shutdown” function.
DISCON-RETARDING= *unchanged
The setting for the function remains unchanged.
DISCON-RETARDING=ON
The “retarded transport connection shutdown” function is switched on, i.e. a transport connection shutdown initiated by the partner is delayed until the data input queue is processed.
DISCON-RETARDING=OFF
The “retarded transport connection shutdown” function is switched off.
APPL-CLOSE-MSG=...
Controls the “APPLICATION CLOSED message” function.
APPL-CLOSE-MSG= *unchanged
The setting for the function remains unchanged.
APPL-CLOSE-MSG=ON
The “APPLICATION CLOSED message” function is switched on, i.e. console message BCA088F is generated.
APPL-CLOSE-MSG=OFF
The “APPLICATION CLOSED message” function is switched off.
NET-ENTRY-CHECK=...
Controls the “network interface check” function.
NET-ENTRY-CHECK= *unchanged
The setting for the function remains unchanged.
NET-ENTRY-CHECK=ON
The “network interface check” function is switched on, i.e. the Network Layer discards the data of a route which arrive on an incorrect network interface.
NET-ENTRY-CHECK=OFF
The “network interface check” function is switched off.
ACCEPT-MSG=...
Controls the “ACCEPT message” function.
ACCEPT-MSG= *unchanged
The setting for the function remains unchanged.
ACCEPT-MSG=ON
The “ACCEPT message” function is switched on, i.e. console message BCA0765 is generated for commands from the SOF or command files.
ACCEPT-MSG=OFF
The “ACCEPT message” function is switched off.
Command logging
For reasons of compatibility, the processing acknowledgment is supplied in news BCA0763 if it is positive and in news BCA0762 if it is negative, followed by the message NBR0740. In addition, for positive acknowledgments, the messages BCA062C, BCA084B and BCA0849 may also appear.
A description of the error messages that may be issued during command processing is provided in the table below.
Command return codes
(SC2) | Maincode | Meaning |
| CMD0001 | Command successfully processed |
| BCA062D | No parameters were changed |
| BCA0768 | Syntax error in command |
| BCA07A0 | Processor is unknown |
| BCA07A1 | Route is unknown |
| BCA07A2 | Line is unknown |
| BCA07A5 | VLAN device is unknown |
| BCA07AA | VLAN line is unknown |
| BCA083A | BCAM-LTS is not active |
| BCA0814 | BCAM is being terminated abnormally |
| BCA0816 | BCAM is terminating |
| BCA0766 | /BCAM is not active |