SHOW-BCAM-ATTRIBUTES / SHBCAM: Show mode parameters

&pagelevel(3)&pagelevel

You use the SHOW-BCAM-ATTRIBUTES command to display the settings of the BCAM mode parameters.

In order to support SNMP management, SHOW-BCAM-ATTRIBUTES can also be called under the alias SHBCAM.

BS2000-Konsole

BS2000-SDF-Kommando

Kommando-/SOF-Datei

SNMP-Management

Parameterservice

x

x

x


List of valid command sources

SHOW-BCAM-ATTRIBUTES / SHBCAM Show BCAM mode parameters

SELECT = *MONITORINGS(...) / *OPTIONS(...) / *PARAMETERS(...) / *START- PARAMETERS(...) / * TIMER (...)


*MONITORINGS(...)



|


RECORD = *ALL , ... / list-poss (16): TRANSFER / RES-MEMORY / TR-DATA /



|







PAG-MEMORY / CONNECTIONS / MODIFY-CONNECTION / DATAGRAM / LOOPBACK /



|







SIH-TIME / LAYER2 , ... / L2 , ... / LAYER4 / L4 / ROUTING /



|







VLAN-DEVICE, ... / VLAN-LINE, ...



|



*ALL , ... / ...



|




|


LINE = *ALL / <line-name 1 .. 8>



|




|


,DEVICE = *ALL / <device-name 1 .. 8>



|



LAYER2 , ... / L2 , ...



|




|


LINE = *ALL / <line-name 1 .. 8>



|



VLAN-DEVICE , ...



|




|


DEVICE = *ALL / <device-name 1 .. 8>



|



VLAN-LINE , ...



|




|


LINE = *ALL / <line-name 1 .. 8>


*OPTIONS(...)



|


OPTION = *ALL , ... / list-poss (41):



|







AUTOMATIC-ES-CREATE /



|







DEVICE-LPDU-SIZE-USAGE / IP-ROUTING / ISO8473-ROUTING /



|







CMDFILE-CONTINUATION / BROADCAST, ... / MULTICAST, ... / CHECKSUM /



|







ARP / RARP / ERROR-REPORT / ISO9542 / AUTO-ROUTE-SWITCHING /



|







PERIODIC-FILE-ACCESS / SHORT-HOLDING-TIME /



|







STOP-ROUTER-SEARCH / ARP-SWITCH /



|







ROUTER-REDUNDANCE / SWITCH-LOCAL-ROUTER / SERVER-PORTS /



|







NET-ROUTER-USAGE / REDIRECT-ON-QUERY / MSG-REPLY / SNMP-WRITE /



|







ARP-REQUESTS-MAXIMUM / LINE-CONTINUATION /



|







LINE-SUPERVISION / NSDU-MODIFICATION /



|







JOIN-MULTICAST-GROUP / SLOW-POLL, ... / MAXTSDU-FOR-CREATE /



|







REMOTE-SERVER-PORTS / IP-RANGE / IPV6 / IPV6-AUTO-CONFIG /



|







IPV6-VLAN-AUTO-CONFIG / IPV6-PREFIX-LEN-CTRL



|







ARP-AT-ROUTE-ACTIVATION / OSPF-USAGE / DNS-USAGE /



|


TCP-KEEP-ALIVE ,DEVICE-LPDU-SIZE-USAGE



|



*ALL, ... / BROADCAST, ... / MULTICAST, ... / SLOW-POLL, ...



|




|


LINE = *all / <line-name 1 .. 8>


*PARAMETERS(...)



|


PARAMETER = *ALL, ... / list-poss (24): CELL-DOUBLING /



|







DISCON-RETARDING / APPL-CLOSE-MSG / ACCEPT-MSG /



|







NET-ENTRY-CHECK / TRACE-INFO / TRACE-LENGTH,TRACE=...



|



*ALL, ...



|




|


LINE = *all / <line-name 1 .. 8>



|




|


,DEVICE = *all / <device-name 1 .. 8>



|



TRACE-LENGTH ,TRACE=, ...



|




|


TRACE = *ALL / TRANS / PORT , ... / VLAN-DEVICE , .../ VLAN-LINE , ...



|




|



PORT , ...



|




|




|

LINE = *ALL / <line-name 1 .. 8>



|




|



VLAN-DEVICE , ...



|




|




|

DEVICE = *all / <device-name 1 .. 8>



|




|



VLAN-LINE , ...



|




|




|

LINE = *all / <line-name 1 .. 8>


*START-PARAMETERS(...)



|


START-PARAMETER = *ALL / list-poss (8): LIMITS / MSG / REMOTE-IP-NSDU /



|







PROCESSOR-TABLE / APPLICATION-TABLE / SOCKETHOST-TABLE



|







FQDN-TABLE / SERVICES-TABLE


*TIMER(...)



|


TIMER = *ALL / list-poss (16): LETT / CONN / WARN / WINDOW /



|



CONFIGURATION / IP-LIFFETIME / INTF-LIFFETIME / I-REASSEMBLY / DATAGRAM /



|



RETRANSMISSON / ARP-SUPERVISION / MAX-MSCF-DELAY

SELECT=
SELECT enables you to choose which monitoring settings, BCAM mode options, BCAM diagnostic parameters, BCAM startup parameters or timer intervals are shown.
The display occurs with the console message BCA084A.

SELECT=*MONITORINGS(RECORD=...)
Specifies which monitoring settings defined via the BCMON command (see section "BCMON: Control BCAM monitoring") are shown.
The values can also be specified as a list enclosed in parantheses (list-poss).

RECORD=*ALL
All monitoring settings are output.

LINE=...
Name of the line for which the monitoring settings are to be output.

LINE=*all
All line-specific monitoring settings are shown for all lines.

LINE=<line-name 1..8>
All line-specific monitoring settings for the line defined with <line-name> are shown.

DEVICE=...
Name of the VLAN device for which the monitoring settings are to be shown.

DEVICE=*all
All VLAN-device-specific monitoring settings are shown for all VLAN devices.

DEVICE=<device-name 1..8>
All VLAN-device-specific monitoring settings are shown for the VLAN device defined with <device-name>.

RECORD=TRANSFER
Shows the monitoring settings for connection-oriented data transfers.

RECORD=RES-MEMORY
Shows the monitoring settings for resident memory.

RECORD=TR-DATA
Shows the monitoring settings for TR memory.

RECORD=PAG-MEMORY
Shows the monitoring settings for pageable memory.

RECORD=CONNECTIONS
Shows the monitoring settings for transport connections.

RECORD=MODIFY-CONNECTION
Shows the monitoring settings for connection activities.

RECORD=DATAGRAM
Shows the monitoring settings for connectionless data transfers (UDP).

RECORD=LOOPBACK
Shows the monitoring settings for LOOPBACK data transfers.

RECORD=SIH-TIME
Shows the monitoring settings for SIH-TIME.

RECORD=LAYER2 / L2
Shows the monitoring settings for Layer 2.

LINE=...
Name of the line for which the Layer 2-relevant settings are shown.

LINE=*all
The Layer 2-relevant settings for all lines are shown.

LINE=<line-name 1..8>
The Layer 2-relevant settings for the line defined with <line-name> are shown.

RECORD=LAYER4 / L4
Shows the monitoring settings for Layer 4.

RECORD=ROUTING
Shows the monitoring settings for routing.

RECORD=VLAN-DEVICE
Shows the VLAN device settings for VLAN devices.

DEVICE=...
Name of the VLAN device for which the monitoring settings are shown.

DEVICE=*all
All VLAN-device-specific monitoring settings are shown for all VLAN devices.

DEVICE=<device-name 1..8>
All VLAN-device-specific monitoring settings are shown for the VLAN device defined with <device-name>.

RECORD=VLAN-LINE
The VLAN line settings for VLAN lines are shown.

LINE=...
Name of the VLAN line for which the monitoring settings are shown.

LINE=*all
All VLAN-line-specific monitoring settings are shown for all VLAN lines.

LINE=<line-name 1..8>
All VLAN-line-specific monitoring settings are shown for the VLAN line defined with <line-name>.

SELECT=*OPTIONS(OPTION=...)
Specifies which BCAM mode options defined via the BCOPTION command (see section "BCOPTION: Change mode options") are shown.
The values can also be specified as a list enclosed in parantheses (list-poss).

OPTION=*ALL
All BCAM mode options are shown.

LINE=...
Name of the line for which the BCAM mode options are to be shown.

LINE=*all
All line-specific BCAM mode options for all lines are shown.

LINE=<line-name 1..8>
All line-specific BCAM mode options for the line defined with <line-name> are shown.

OPTION=AUTOMATIC-ES-CREATE
Shows the setting for the "AUTOMATIC-ES-CREATE" option.

OPTION=DEVICE-LPDU-SIZE-USAGE
Shows the setting for the "DEVICE-LPDU-SIZE-USAGE" option.

OPTION=IP-ROUTING
Shows the setting for the "IP-ROUTING" option.

OPTION=ISO8473-ROUTING
Shows the setting for the "ISO8473-ROUTING" option.

OPTION=CMDFILE-CONTINUATION
The setting for the "CMDFILE-CONTINUATION" option is displayed (see section "BCOPTION: Change mode options").

OPTION=BROADCAST
Shows the setting for the "BROADCAST" option.

LINE=...
Name of the line for which the setting of the "BROADCAST" option is to be shown.

LINE=*all
The setting of the "BROADCAST" option for all lines is shown.

LINE=<line-name 1..8>
The setting of the "BROADCAST" option for the line defined with <line-name> is shown.

OPTION=MULTICAST
Shows the setting of the "MULTICAST" option.

LINE=...
Name of the line for which the setting of the "MULTICAST" option is to be shown.

LINE=*all
The setting of the "MULTICAST" option for all lines is shown.

LINE=<line-name 1..8>
The setting of the "MULTICAST" option for the line defined with <line-name> is shown.

OPTION=CHECKSUM
Shows the setting of the "CHECKSUM" option.

OPTION=ARP
Shows the setting of the "ARP" option.

OPTION=RARP
Shows the setting of the "RARP" option.

OPTION=ERROR-REPORT
Shows the setting of the "ERROR-REPORT" option.

OPTION=ISO9542
Shows the setting of the "ISO9542" option.

OPTION=AUTO-ROUTE-SWITCHING
Shows the setting of the "AUTO-ROUTE-SWITCHING" option.

OPTION=PERIODIC-FILE-ACCESS
Shows the setting of the "PERIODIC-FILE-ACCESS" option.

OPTION=SHORT-HOLDING-TIME
Shows the setting of the "SHORT-HOLDING-TIME" option.

OPTION=STOP-ROUTER-SEARCH
Shows the setting of the "STOP-ROUTER-SEARCH" option.

OPTION=ARP-SWITCH
Shows the setting of the "ARP-SWITCH" option.

OPTION=ROUTER-REDUNDANCE
Shows the setting of the "ROUTER-REDUNDANCE" option.

OPTION=SWITCH-LOCAL-ROUTER
Shows the setting of the "SWITCH-LOCAL-ROUTER" option.

OPTION=SERVER-PORTS
Shows the setting of the "SERVER-PORTS" option.

OPTION=NET-ROUTER-USAGE
Shows the setting of the "NET-ROUTER-USAGE" option.

OPTION=REDIRECT-ON-QUERY
Shows the setting of the "REDIRECT-ON-QUERY" option.

OPTION=MSG-REPLY
Shows the setting of the "MSG-REPLY" option.

OPTION=SNMP-WRITE
Shows the setting of the "SNMP-WRITE" option.

OPTION=ARP-REQUESTS-MAXIMUM
Shows the setting of the "ARP-REQUESTS-MAXIMUM" option.

OPTION=LINE-CONTINUATION
Shows the setting of the "LINE-CONTINUATION" option.

OPTION=LINE-SUPERVISION
Shows the setting of the "LINE-SUPERVISION" option.

OPTION=NSDU-MODIFICATION
Shows the setting of the "NSDU-MODIFICATION" option.

OPTION=JOIN-MULTICAST-GROUP
Shows the setting of the "JOIN-MULTICAST-GROUP" option.

OPTION=SLOW-POLL
Shows the setting of the "SLOW-POLL" option.

LINE=...
Name of the line for which the setting of the "SLOW-POLL" option is to be shown.

LINE=*all
The setting of the "SLOW-POLL" option for all lines is shown.

LINE=<line-name 1..8>
Shows the setting of the "SLOW-POLL" option for the line defined with <line-name> is shown.

OPTION=MAXTSDU-FOR-CREATE
Shows the setting of the "MAXTSDU-FOR-CREATE" option.

OPTION=REMOTE-SERVER-PORTS
Shows the setting of the "REMOTE-SERVER-PORTS" option.

OPTION=IP-RANGE
Shows the setting of the "IP-RANGE" option.

OPTION=IPV6
Shows the setting of the "IPV6" option.

OPTION=IPV6-AUTO-CONFIG
Shows the setting of the "IPV6-AUTO-CONFIG" option.

OPTION=IPV6-VLAN-AUTO-CONFIG
Shows the setting of the "IPV6-VLAN-AUTO-CONFIG" option.

OPTION=IPV6-PREFIX-LEN-CRTL
Shows the setting of the "IPV6-PREFIX-LEN-CRTL" option.

OPTION=ARP-AT-ROUTE-ACTIVATION
Shows the setting of the "ARP-AT-ROUTE-ACTIVATION" option.

OPTION=OSPF-USAGE
Shows the setting of the "OSPF-USAGE" option.

OPTION=DNS-USAGE
Shows the setting of the "DNS-USAGE" option.

OPTION=TCP-KEEP-ALIVE
Shows the setting of the "TCP-KEEP-ALIVE" option.

OPTION=DEVICE-LPDU-SIZE-USAGE
Shows the setting of the "DEVICE-LPDU-SIZE-USAGE" option.

SELECT=*PARAMETERS(PARAMETER=...)
Specifies which BCAM diagnostic parameters defined via the BCSET command (see section "BCSET: Set diagnostics and maintenance parameters") are shown.
The values can also be specified as a list enclosed in parantheses (list-poss).

PARAMETER=*ALL
All BCAM diagnostic parameters are shown.

LINE=...
Name of the line for which the BCAM diagnostic parameters are to be shown.

LINE=*all
All line-specific BCAM diagnostic parameters for all lines are shown.

LINE=<line-name 1..8>
All line-specific BCAM diagnostic parameters for the line defined with <line-name> are shown.

DEVICE=...
Name of the VLAN device for which the BCAM diagnostic parameters are shown.

DEVICE=*ALL
All device-specific BCAM diagnostic parameters for all VLAN devices are shown.

DEVICE=<device-name 1..8>
All device-specific BCAM diagnostic parameters for the VLAN device defined with <device-name> are shown.

PARAMETER=CELL-DOUBLING
The setting of the BCAM diagnostic function to "check for cell doubling" is shown.

PARAMETER=DISCON-RETARDING
The setting of the BCAM diagnostic function for "disconnect retarding", i.e. delays in clearing the transport connection, is shown.

PARAMETER=APPL-CLOSE-MSG
Shows the setting of the BCAM diagnostic function "APPLICATION CLOSED message".

PARAMETER=ACCEPT-MSG
Shows the setting of the BCAM diagnostic function "ACCEPT message".

PARAMETER=NET-ENTRY-CHECK
Shows the setting of the BCAM diagnostic function "net entry check".

PARAMETER=TRACE-INFO
Shows whether the output of additional trace information is set.

PARAMETER=TRACE-LENGTH,TRACE=...
Shows the setting of the trace lengths.

TRACE=
Defines for which traces the lengths are to be shown.

TRACE=*ALL
The length settings are shown for all traces.

TRACE=TRANS
The length settings are shown for the traces DCM.BCAM.TRANS and DCM.BCAM.LOC.

TRACE=PORT,...
The settings of the lengths for the port trace are shown.

LINE=...
Defines for which lines the length of the port trace is to be shown.

LINE=*all
The length settings for all port traces are shown.

LINE=<line-name 1..8>
The length setting for the port trace identified with <line-name> is shown.

TRACE=VLAN-DEVICE,...
The setting of the lengths for the port trace is shown.

DEVICE=...
Defines the VLAN devices for which the lengths of the V port traces are to be shown.

DEVICE=*all
The settings of the lengths are shown for all V port traces.

DEVICE=<device-name 1..8>
The length setting for the V port trace identified with <device-name> is shown. 

TRACE=VLAN-LINE,...

LINE=...
Defines the VLAN lines for which the lengths of the V port traces are to be shown.

LINE=*all
The settings of the lengths are shown for all V port traces.

LINE=<line-name 1..8>
The length setting for the V port trace identified with <line-name> is shown.

SELECT=*START-PARAMETERS(START-PARAMETER=...)
Specifies which BCAM startup parameters defined via the DCSTART ("DCSTART: Start the data communication system in BS2000"ff), DCOPT ("DCOPT: Predefine DCSTART parameters"ff) or BCMOD ("BCMOD: Modify limit values specified with DCSTART"ff) command are shown.
The values can also be specified as a list enclosed by brackets (list-poss).

START-PARAMETER=*ALL
All BCAM start parameters are shown.

START-PARAMETER=LIMITS
Shows the setting for the start parameters "PAGMEM", "RESMEM", "MAXCNN", "MAXNPA", "MAXPNT", "PRIVPORT#" and "FREEPORT#".

START-PARAMETER=MSG
Shows the set message scope (MSG).

START-PARAMETER=REMOTE-IP-NSDU
Shows the set NSDU length (REMOTE-IP-NSDU) for IP routes that run via at least one router.

START-PARAMETER=PROCESSOR-TABLE
Shows the name set for the PROCESSOR-TABLE (processor file).

START-PARAMETER=APPLICATION-TABLE
Shows the name set for the APPLICATION-TABLE (application file).

START-PARAMETER=SOCKETHOST-TABLE
Shows the name set for the SOCKETHOST-TABLE (socket host file).

START-PARAMETER=FQDN-TABLE
Shows the name set for the FQDN-TABLE (FQDN file).

START-PARAMETER=SERVICES-TABLE
Shows the name set for the SERVICES-TABLE (services file).

SELECT=*TIMER(TIMER=...)
Specifies which BCAM timers defined via the BCTIMES command (see "BCTIMES: Define BCAM time intervals"ff) are shown.
The values can also be specified as a list enclosed in parantheses (list-poss).

TIMER=*ALL
All BCAM timers are shown.

TIMER=LETT
The setting of the Letter timer is shown.

TIMER=CONN
The setting of the Connection timer is shown.

TIMER=WARN
The setting of the Warn timer is shown.

TIMER=WINDOW
The setting of the Window timer is shown.

TIMER=CONFIGURATION
The setting of the Configuration timer is shown.

TIMER=IP-LIFETIME
The setting of the IP-Lifetime timer is shown.

TIMER=INTF-LIFETIME
The setting of the ISO8473-Lifetime timer is shown.

TIMER=I-REASSEMBLY
The setting of the Reassembly timer is shown.

TIMER=DATAGRAM
The setting of the Datagram timer is shown.

TIMER=RETRANSMISSION
The setting of the Retransmission timer is shown.

TIMER=ARP-SUPERVISION
The setting of the ARP-Supervision timer is shown.

TIMER=MAX-MSCF-DELAY
The setting of the MAX-MSCF-DELAY timer is shown.

Command logging

For reasons of compatibility, the processing acknowledgment is supplied in news BCA0731 if it is positive and in news BCA08EF if it is negative. In addition, for positive acknowledgments, the messages BCA084A, BCA08F5, BCA08F8 and BCA08F9 may also appear.
A description of the error messages that can be issued during command processing is provided in the table below.

Command return codes

(SC2)      SC1

Maincode

Meaning

   0        0

CMD0001

Command successfully processed

   0        1

BCA0768

Syntax error in command

   0       64

BCA07A2

Line is unknown

   0       64

BCA07A5

Device is unknown

   0       64

BCA07AA

VLAN line is unknown

   0       64

BCA08EF

Nothing to be displayed was found

   0      128

BCA0814

BCAM is being terminated abnormally

   0      128

BCA0816

BCAM is terminating

   0      130

BCA0766

BCAM is not active