This report contains information on the input/output operations on all files of selected disk devices.
Report output
The REPORT DISK_FILE statement is used to request the output of the DISK FILE report. The report can only be output if the SM2 administrator has
defines the disk devices to be monitored using the SET-DISK-FILE-PARAMETERS statement
started the monitoring process using the statement START-MEASUREMENT-PROGRAM TYPE=*DISK-FILE
The statistics for each disk devices are output in a separate screen. All files are displayed to the privileged user. Nonprivileged users only get to see files with their own ID.
Overflow screens can be requested for this report. The output of the monitored data is sorted on the basis of READ and WRITE.
HOST0001 SM2 DISK FILE CYCLE: 60 S <date> <time> READ | WRITE | FILENAME (MN: B3A3, VSN: 6VS1.1) ---------+---------+------------------------------------------------------- 0.0 | 0.0 | *OVERRUNS 0.4 | 4.3 | :2OS6:$UID.FILE1 3.0 | 0.0 | :2OS6:$UID.FILE2 1.1 | 1.6 | :2OS6:$UID.FILE3 0.6 | 0.0 | :2OS6:$UID.FILE4
Monitoring information
READ | Number of read operations per second |
WRITE | Number of write operations per second |
FILENAME | Name of the monitored file |
MN | Mnemonic device name of the monitored disk device |
VSN | VSN of the monitored disk device |