STOP-MEASUREMENT-PROGRAM Terminate monitoring program run

This statement is used to terminate the monitoring programs specified under TYPE.

Format

STOP-MEASUREMENT-PROGRAM                                                                                                             

TYPE = *ALL / list-poss(28): *BCAM-CONNECTION / *CHANNEL-IO / *CMS / *COSMOS / *DAB / *DISK-FILE

*DLM / *FILE / *HSMS / *ISAM / *MSCF / *NSM / *OPENFT / *PERIODIC-TASK /

*POSIX / *PUBSET / *RESPONSETIME / *SAMPLING-DEVICE / *SERVICETIME /

*SESAM-SQL / *SVC / *SYSTEM / *TASK / *TCP-IP / *TLM / *UDS-SQL / *UTM / *VM

Operands

TYPE =
Specifies the name of monitoring program to be terminated, see chapter "SM2 monitoring programs".

TYPE = *ALL
Terminates all active monitoring programs (except SAMPLING-DEVICE).