Information on the utilization of imported SF pubsets or volume sets is output in the PUBSET report.
Report output
The REPORT PUBSET statement is used to request the output of the PUBSET report.
The report can only be output if the SM2 administrator has activated the monitoring process using the statement START-MEASUREMENT-PROGRAM TYPE=*PUBSET.
Overflow screens may be requested for this report.
The monitored data output is sorted under the category USED.
HOST0001 SM2 PUBSET CYCLE: 60 S <date> <time> | CATID | TYP | # | SAT | CAPACITY | USED | | | | VOL | LEV | GB | % | +-------------+-----+-----+-----+----------+------+ | 2PFS | SF | 1 | 0 | 2.3 | 98 | | 4VS1 (1O04) | VS | 18 | 0 | 41.7 | 98 | | M1D1 | SF | 11 | 1 | 25.5 | 97 | | 1CV4 (1O04) | VS | 32 | 0 | 74.1 | 96 | | CVS7 (2OSC) | VS | 6 | 1 | 13.9 | 93 |
Monitoring information
The individual entries have the following meanings:
CATID | Identifier of an SF pubset or volume set. In the case of volume sets the ID of the SM pubset is subsequently output. |
TYP | Type of monitored object:
|
# VOL | Number of volumes |
SAT LEV | Saturation level (0-6) |
CAPACITY GB | Capacity in GB |
USED % | Utilization in % |