Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

Messages K147 - K189

K147

Sign-on for &USRTYPE user &USER not successful.
&PTRM/&PRNM/&BCAP/&LTRM reason: U&REA7

&USRTYP contains the following values:

  • CONNECTION at sign-on of the connection user ID of a connection to a UPIC client or transport system application

  • CLIENT at sign-on of a genuine user ID via TS application, UPIC client or OSI TP partner.

The values in &REA7 have the following meanings:

&REA7

Meaning

U1

The specified USER does not exist.

U2

The specified USER is locked.

U3

Somebody has already signed on with this USER name.

U4

The “old” password specified is incorrect.

U5

The new password specified cannot be used.

U6

There is no card reader available.

U7

The card information is incorrect

U8

It is not possible to sign on at the moment:

  • because of a resource bottleneck

  • because the maximum number of users who can be signed on simultaneously has already been reached

  • because a password could not be changed, since an inverse KDCDEF is currently running.

U9

Sign-on not possible due to lack of Kerberos support.

U10

The current LTERM partner is not authorized to continue the service.

U11

The password is no longer valid.
The password must be changed by the administrator.
When the user signs on using an OSI TP association, the password cannot be changed (nor can it in an application with grace sign-on).

U12

The new password does not fulfill the requirements  of the generated complexity level

U13

The new password is too short.

U14

The password passed by KDCUPD does not fulfil the generated complexity requirements or is too short.

U15

A transaction restart is necessary for the specified user.

U16

The open service cannot be continued from this partner type.

U17

The administrator entered SHUT WARN; normal users can no longer sign on to the application (an administrator can still sign on).

U18

The encryption mechanism required for continuing the open service is not available on the connection

U19

The validity period of the password has expired. Because Grace Sign-On is generated, sign-on can be repeated by transferring a new password.

U22

The specified USER does not exist in the cluster user file.

U23

Someone else has already signed on to another node with this USER.

U24

It is currently not possible to sign on because the cluster user file could not be locked in the generated time (CLUSTER statement, FILE-LOCK-TIMER-SEC parameter, FILE-LOCK-RETRY parameter).

U25

It is not possible to sign on at this node application because the user has a service that is bound to another node application and may not be terminated.

U26

Sign-on rejected because the open service belonging to the user has a transaction in the PTC state but no service restart has been requested.

K149

Internal diagnostic information &DIA5

An event has occurred which is logged with diagnostic information. &DIA5 is the internal UTM diagnostic information.

K150

RSO error &RSORC &RSO2RC &RSOMSG when calling subsystem RSO with action &RSOOPC

The insert &RSOOPC describes the RSO call in which the error occurred and has the following meaning:

RSOOPC

Meaning

X‘01‘

Reserve Printer

X‘02‘

Print Message

X‘03‘

Release Printer

X‘04‘

Invalidate Bourse

X‘05‘

Receive Info: Information on the printer or printer jobs

X‘06‘

Receive OLTP interfaces version number

The inserts &RSORC, &RSO2RC and &RSOMSG describe the synchronous and
asynchronous return code and the RSO error message. The RSO error message
can be obtained from the RSO manual.

If the asynchronous return code is not X'00000000', then the error occurred during
the execution of the preceding job. In this case, the operation code of the preceding
call can be found in byte 4 and the return code in bytes 5 to 8 of the insert
RSOANNO:

X'56'

undef

undef

Opcode

R e t u r n c o d e

If the synchronous return code is not X'00000000' then the error occurred in the
current &RSOACT call. The content of the insert &RSOANNO is then irrelevant.

If both the synchronous and the asynchronous return codes are X'00000000' then
the RSO error message indicates a problem.

The return code (SC2 SC1 MC) consists of the components subcode 2 (SC2,
always X‘00‘), subcode 1 (SC1) and main code (MC).

SC1

MC

Meaning

X‘00‘X‘0000‘

The function was executed without error.

X‘01‘







X‘0003‘

Function call with invalid action.

X‘0004‘

Length of the RSO macro OLTPRQX passed in the FPUT/DPUT RP by the UTM program unit is incorrect.

X‘0005‘

Version of the RSO macro OLTPRQX passed in the FPUT/DPUT RP by the UTM program unit is incorrect.

X‘0006‘

Function/unit of the RSO macro OLTPRQX passed in the FPUT/DPUT RP by the UTM program unit is incorrect.

X‘0011‘

Character set name (CCSNAME) incorrect

X‘000A‘

RSO buffer size too small (see RSO command MODIFY-SPOOL-PARAMETER).

X‘FFFF‘

Unit or function not supported.

X‘02‘


X‘0006‘

Printer in release process. It will soon be available.

X‘FFFF‘

Function not available.

X‘03‘

X‘FFFF‘

Version not supported.

X‘20‘







X‘0001‘

An error was reported during a memory request.

X‘0003‘

Printer is already reserved by another application (as of RSO V3.2A).

X‘0004‘

This printer is already reserved.

X‘0005‘

An error occurred when creating the OLTP controller.

X‘0009‘

An error occurred when using the bourse interface.

X‘000F‘

An error occurred when using the memory pool.

X‘0010‘

An inconsistency in the internal tables was detected.

X‘40‘





X‘0007‘

The printer is currently being used.

X‘0012‘

Character set name (CCSNAME) unknown

X‘0013‘

XHCS error in RSO

X‘000B‘

An error occurred on accessing the printer.

X‘000D‘

UTM does not have any access rights for the device (see the MODIFY-PRINTER-OUTPUT command).

X‘41‘





X‘0002‘

Printer not reserved by UTM or not started (see RSO command START-PRINTER-OUTPUT).

X‘0006‘

The printer is currently being released because the STOP-PRINTER-OUTPUT command was issued.

X‘0008‘

Printer released internally as a result of an internal error (recovery).

X‘000C‘

Printer cannot be reserved due to recovery.

X‘FFFF‘

RSO subsystem not loaded.

X‘42‘

X‘FFFF‘

RSO subsystem not connected.

X‘80‘

X‘000E‘

An error occurred on accessing the printer.

X‘81‘

X‘FFFF‘

RSO subsystem temporarily unavailable.

X‘82‘

X‘FFFF‘

RSO subsystem halted or stopped.

K151

Run of inverse KDCDEF terminated. Return code: &IDEFRC &DMSE &FNAM

The insert &IDEFRC contains a 16-digit return code for the inverse KDCDEF. The return code comprises two 8-digit printable numbers.

The first 8 digits have the following meanings:

First 8 digits

Meaning

00000000

The inverse KDCDEF was terminated normally.

00000001

A file handling error occurred.

00000002

A memory bottleneck occurred.

00000003

No KDCDEF statements were generated.

Digits 9 - 16 are only relevant if the first 8 digits contain 00000001. In this event, digits 9 - 16 contain a more detailed description of the error which occurred.
In all other cases, digits 9 - 16 contain 00000000.

Digits 9 - 16

Meaning

00000001

Invalid name for an output file.

00000002

Output file could not be created.

00000003

Output file could not be opened.

00000004

Output file could not be written.

00000005

Output file already exists and is not of the type SAM.

The insert &DMSE contains the printable DMS error code if an error occurs during file handling and digits 9 - 16 of the insert &IDEFRC contain one of the values 00000002, 00000003 or 00000004.

The insert &FNAM contains the name of the file for which the error occurred.

K152

Heuristic report: &COND &MTYPE &OSLPAP &USER &LTAC &AAIS &AAID

The inserts have the following meaning

&COND

Meaning

MIX

The server reported data inconsistency.
This is not possible with an asynchronous message to a UTM application.

HAZ

Possible data inconsistency. Connection to OSI TP job receiver (subordinate) was lost after a PREPARE was sent and the OSI TP job submitter (superior) had not carried out a backup.
The transaction is rolled back on the job submitter and a asynchronous message is sent again. The transaction is also rolled back in a UTM job receiver, or an asynchronous message is rejected (immediately after a restart), so that the data is consistent.

&MTYPE

Meaning

DIAL

A dialog message was sent.

ASYN

An asynchronous message was sent.

&OSLPAP:

Name of the partner application.

&USER:

Name of the user who issued the job.

&LTAC:

for an asynchronous message: LTAC name of the job for a dialog
massage: TAC of the transaction for which inconsistency is possible

&AAIS:

Size of the atomic action identifier in bytes.

&AAID:

contains the encoded atomic action identifier (up to 64 bytes).

K153

Info for FHS message: &PTRM/&PRNM/&BCAP/&LTRM/&USER

This message is generated if FHS requests openUTM to output a message to SYSOUT. The message allows you to assign the user and LTERM partner to the FHS message. This information can be required in the event of problems with OMNIS (with and without MUX connections) in order to identify where the problem originated.

K154

SOCKET message: &PTRM/&PRNM/&BCAP/&LTRM &TCPCL &TCPRC

The inserts of the message have the following meaning:

Insert

Meaning

&TCPCL

internal socket function or internal socket event

&TCPRC

Diagnostic Word

&TCPCL is output in printable form:

&TCPCL

Meaning

OPEN_EVENTGROUP

Open the event group

ATTACH IPv4

Create a socket for the address family AF_INET

ATTACH IPv6

Create a socket for the address family AF_INET6

ATTACH AMBIGUOUS

A socket with the same port number has already been generated.

EVENT

Pick up an event

CONNECTION_REQ

Request the establishment of a connection

CONNECTION_RSP

Confirm the establishment of a connection

DISCONNECT_REQ

Clear connection

DATA_REQ

Send data

DATA_IND

Receive data

GET_HOST_BY_ADDR

Determine computer name of an IPv4 address

GET_IPNODE_BY_ADDR

Determine host name corresponding to an IPv6 address

GET_HOST_BY_NAME

Determine IPv4 address of a computer

GET_IPNODE_BY_NAME

Determine IPv6 address corresponding to a host Name

The values of the diagnostic word are 4 byte long and are specified in hexadecimal notation. They correspond to the return codes of the “YDBSOC” interface.

General return codes

The following return codes can occur at every call of the TCP/IP functions:

Return code

Meaning

Subcode

Main code



2

1

2

1

00

01

FF

FF

Invalid unit or function in the standard header

00

02

FF

FF

Requested function not available

00

03

FF

FF

Invalid version number in standard header

00

41

FF

FF

Subsystem not present or not started

00

20

00

30

Internal BCAM error

00

82

00

04

BCAM is not active

0C

40

02

1C

BCAM shutdown running

14

40

02

20

SOCKET of BCAM administrator closed

00

04

00

44

Parameter list not accessible



&TCPCL = OPEN_EVENTGROUP

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

OPEN-EVENTGROUP executed successfully

04

80

06

1C

No memory available for SUB-TCB

04

80

0C

1C

No memory available for layer 4 CB

04

80

10

1C

No memory available for local event group control block

04

80

11

1C

No memory available for global event group control block

04

80

14

1C

No memory available for event group name

08

40

01

1C

BCAM shutdown announced

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing

00

01

02

51

Event group already opened by this task

00

01

10

51

USERID of the owner of the event group could not be determined

00

01

11

51

Specification of EVENTGROUP_NAME is not permitted for a TU user



&TCPCL = CLOSE_EVENTGROUP

Return code

Meaning

Subcode

Main code


2

1

2

1

00

01

00

00

CLOSE_EVENTGROUP executed successfully

04

80

0C

1C

No memory available for layer 4 CB

08

40

01

1C

BCAM shutdown announced

00

80

00

28

Event group cannot be closed at the moment (call can be repeated later)

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing

00

01

04

51

Task not connected to the event group

00

01

07

51

Invalid EVENTGROUP_ID

00

01

13

51

Event group cannot be closed at the moment because it is still being used



&TCPCL = ATTACH IPv4 or ATTACH IPv6

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

SOCKET executed successfully

00

01

33

08

Specified port number already being used

04

80

04

1C

No memory available for APPCB

04

80

06

1C

No memory available for SUB-TCB

04

80

09

1C

No memory available for ENACB

04

80

0C

1C

No memory available for layer 4 CB

04

80

0D

1C

No free ABID available

04

80

0E

1C

No free port number available

04

80

13

1C

No name server entry available

08

40

01

1C

BCAM shutdown announced

10

82

00

1C

Global limit value for the number of open SOCKETs reached

10

01

00

20

SOCKET already opened by this task

18

40

01

20

SOCKET is currently being forcibly closed by the BCAM administrator

28

82

00

20

Local task limit value for the number of open SOCKETs

00

80

00

28

SOCKET currently not possible (call can be repeated later)

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing

00

01

01

50

Unknown host

00

01

02

50

Host not active

00

01

04

51

Task not connected to the event group

00

01

07

51

Invalid EVENTGROUP_ID

00

01

10

53

USER_ID could not be determined



&TCPCL = DETACH

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

CLOSE_SOCKET executed successfully

00

01

03

08

SOCKET_ID not specified

04

08

0C

1C

No memory available for layer 4 CB

04

01

00

20

SOCKET not opened by this task

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing



&TCPCL = EVENT

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

GET-EVENT executed successfully

00

80

00

28

GET-EVENT currently cannot be executed (call can be repeated later)

00

01

04

51

Task not connected to the event group

00

01

07

51

Invalid EVENTGROUP_ID

00

80

09

51

No event occurred



&TCPCL = CONNECTION_REQ

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

CONNECT executed successfully

00

01

03

08

SOCKET_ID not specified

04

80

02

1C

No free transport reference available

04

80

03

1C

No memory available for ACONCB

04

80

0A

1C

No memory available for ADDRCB-P

04

80

0B

1C

No free CONNECTION_ID available

04

80

0C

1C

No memory available for layer 4 CB

04

80

0E

1C

No free port number available

04

80

15

1C

No memory available for EVOL

08

40

01

1C

BCAM shutdown announced

04

01

00

20

SOCKET not opened by this task

18

40

01

20

SOCKET currently being closed forcibly by the BCAM administrator

20

01

00

20

CONNECT not permitted for SOCKET

24

82

00

20

No further connections permitted for this SOCKET

08

01

00

24

Connection already established

0C

01

00

24

Connection is already being established

18

01

00

24

Partner not known

1C

82

00

24

Partner processor not known

1C

82

01

24

Partner processor not active

1C

82

04

24

Partner IP address not known

1C

82

06

24

Request to establish connection to broadcast address

30

01

00

24

SOCKET not authorized for connection establishment

40

01

05

24

Required interface functionality not supported

40

01

07

24

Interface functionality of partners does not match

40

01

08

24

Level 4 address not available

60

40

00

24

Port number already being used

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing

00

01

04

51

Task not connected to the event group

00

01

07

51

Invalid EVENTGROUP_ID



&TCPCL = CONNECTION_RSP

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

ACCEPT executed successfully

00

01

07

08

CONNECTION_ID not specified

04

80

0C

1C

No memory available for layer 4 CB

08

40

01

1C

BCAM shutdown announced

04

01

00

20

SOCKET not opened by this task

18

40

01

20

SOCKET currently being closed forcibly by the BCAM administrator

04

01

00

24

Invalid CONNECTION_ID

14

01

00

24

No CONNECTION request pending

40

01

05

24

Required interface functionality not supported

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND process.

00

01

04

51

Task not connected to the event group

00

01

07

51

Invalid EVENTGROUP_ID



&TCPCL = DISCONNECT_REQ

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

CLOSE-CONNECTION executed successfully

00

01

07

08

CONNECTION_ID not specified

04

80

0C

1C

No memory available for layer 4 CB

04

01

00

20

SOCKET not opened by this task

18

40

01

20

SOCKET currently being closed forcibly by the BCAM administrator

04

01

00

24

Invalid CONNECTION_ID

64

40

00

24

Connection already being cleared down

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND process.



&TCPCL = DATA_REQ

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

SEND executed successfully

14

00

00

00

SEND executed successfully, but further sending prevented by interface flow control

00

01

07

08

CONNECTION_ID not specified

00

01

26

08

LENGTH_OF_DATA invalid

00

01

13

08

User buffer length = 0

00

01

31

08

User buffer not accessible

00

01

00

14

User data facility too large

04

80

01

1C

No memory available for data buffer

04

80

07

1C

Sending prevented by interface flow control

14

40

00

1C

Waiting for DATA_GO_INDICATION

04

01

00

20

SOCKET not opened by this task

04

01

00

24

Invalid CONNECTION_ID

48

01

00

24

Connection is not in the data transfer phase (not yet fully established)

00

80

00

28

SEND currently cannot be executed (call can be repeated later)



&TCPCL = DATA_IND

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

READ executed successfully

00

01

07

08

CONNECTION_ID not specified

00

01

26

08

length_of_data invalid

00

01

2D

08

No data available

00

01

31

08

User buffer cannot be accessed

00

40

00

10

No data received

04

01

00

20

SOCKET not opened by this task

04

01

00

24

Invalid CONNECTION_ID

48

01

00

24

Connection is not in the data transfer phase (not yet fully established)

00

80

00

28

READ currently cannot be executed (call can be repeated later)

00

40

00

2C

User data lost



&TCPCL = GET_HOST_BY_ADDR

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

GET_HOST_BY_ADDR executed successfully

04

80

0C

1C

No memory available for layer 4 CB

08

40

01

1C

BCAM shutdown announced

00

80

00

28

GET_HOST_BY_ADDR currently not possible (call can be repeated later)

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing

00

01

01

53

Invalid IP address



&TCPCL = GET_HOST_BY_NAME

Return code

Meaning

Subcode

Main code


2

1

2

1

00

00

00

00

GET_HOST_BY_NAME executed successfully

00

01

30

08

Invalid socket host name

04

80

0C

1C

No memory available for layer 4 CB

08

40

01

1C

BCAM shutdown announced

00

80

00

28

GET_HOST_BY_NAME currently not possible (call can be repeated later)

00

20

01

30

System error at startup of CONHAND processing

00

20

02

30

System error waiting for the termination of CONHAND processing



&TCPCL = GET_IPNODE_BY_ADDR

Return code

Meaning

Subcode

Maincode


2

1

2

1

00

00

00

00

GET_IPNODE_BY_ADDR performed successfully

04

80

0C

1C

No memory available for Layer 4 CB

08

40

01

1C

BCAM shutdown announced

00

80

00

28

GET_IPNODE_BY_ADDR not currently possible (repeat call later)

00

20

01

30

System error on starting CONHAND processing

00

20

02

30

System error on waiting for termination of CONHAND processing

00

01

01

53

Invalid IPv6 address



&TCPCL = GET_IPNODE_BY_NAME

Return code

Meaning

Subcode

Maincode


2

1

2

1

00

00

00

00

GET_IPNODE_BY_NAME performed successfully

00

01

30

08

Invalid socket host name

04

80

0C

1C

No memory available for Layer 4 CB

08

40

01

1C

BCAM shutdown announced

00

80

00

28

GET_IPNODE_BY_NAME not currently possible (repeat call later)

00

20

01

30

System error on starting CONHAND processing

00

20

02

30

System error on waiting for termination of CONHAND processing

K155

Your password is expired!
Please enter expired password
> &PAS1 <
Please enter new password
> &PAS2 <
and repeat new password
> &PAS3 <

K156

UTM-UPIC encryption functionality &CRYP  available: &RSLT

K158

Inconsistent value for CPU time used: &CPUTEXT

The calculation of the CPU time used by the user resulted in an inconsistent value.

The message contains the following inserts:

Insert

Meaning

PTRM

Name of the current PTERM

PRNM

Name of the current processor

BCAP

Name of the current BCAM application

LTRM

Name of the current LTERM

USER

Name of the current user

CPUTEXT

NEGATIVE: A negative value was observed
OVERFLOW: Too much time used by the user

CPUBEGIN

CPU time used at the beginning of the period monitored

CPUEND

CPU time used at the end of the period monitored

CPUUSED

CPU time used calculated for the period monitored

CPUCLNT

CPU time actually used by the current user

CPUREAS

Internal diagnostic value

K159

Password for User &USER changed

The password has been changed for the specified user. The message is sent every time the password is changed independently of how the password was changed (administrator, via SIGN CP, etc.)

The message possesses the following inserts:

Insert

Meaning

USER

Name of the user whose password was changed.

ENCPW

Modified password in encrypted form.


This message can be used to transfer modified user passwords to a standby application. To this end, the message destination MSGTAC or USER-DEST must be defined for this message in the private message module. The new user password can be set in encrypted form in the standby application by defining pw_encrypted='Y' via programmed administration KC_MODIFY_OBJECT, object type USER.

Notes:

  • You should note that no UTM-D communication is permitted in the MSGTAC program unit. The modified password cannot therefore be sent directly from the MSGTAC program unit via a UTM-D connection to the standby application.

  • If the application terminates during productive operation and password changes are made during this period then it is possible that the corresponding messages to the MSGTAC program will not be received but will instead be lost.

  • UTM generates the new message for each type of password change and in particular if the password is modified in the standby application. You should make sure that the standby application does not transfer the password back to the productive application in order to avoid any ping-pong effect.

  • You should note that UTM uses different encryption algorithms on different platforms. As a result, the function cannot be used on a cross-platform basis.

  • The passwords should be generated with the same level of complexity in the involved applications since UTM does not check the complexity when entering the encrypted password.

  • In UTM(BS2000), the same host code should be used on the participating hosts so that special characters in passwords always have the same EBCDIC code.

K160

The &TACNTR. transaction of service &TCVG has been rolled back by &RBCAUSER (&RCCC/&RCDC)The message has the following inserts:

Insert

Meaning

PTRM

Name of the current PTERM

PRNM

Name of the current processor

BCAP

Name of the current application

LTRM

Name of the current LTERM

USER

Name of the current user

TCVG

Name of the service TAC in which the transaction was rolled back

TAC

Name of the TAC in which the transaction was rolled back

TACNTR

Number of the rolled back transaction within the service

RBCAUSER

Initiator of the rollback. There are the following values for the initiator,

  • User PEND RS:
    Rollback was triggered by a PEND RS in the program unit.

  • System PEND RS:
    Rollback was triggered by a PEND RS initiated by UTM.

  • User PGWT RB:
    Rollback by triggered by a PGWT RB in the program unit.

  • System PGWT RB:
    Rollback was triggered by a PGWT RB initiated by UTM.

  • User PEND ER:
    Rollback was triggered by a PEND ER/FR in the program unit.

  • System PEND ER:
    Rollback was triggered by a PEND ER initiated by UTM.

  • DBSTATUS OPEN:
    The rollback was triggered during the warm start due to an unsuccessful database status query.

RCCC

Value of the compatible KCRCCC return code

RCDC

Valid of the incompatible KCRCDC return code

K161

Synchronous Periodic Write started for task &TASK

K162

Long IO for task &TASK: &IOPG pages, &IOMS milliseconds

K163

Long Periodic Write for task &TASK: &IOPG pages, &IOMS milliseconds

K164

System file SYSOUT will be switched to file &FNAM.

K165

System file SYSLST will be switched to file &FNAM.

K166

Error &RCHX when switching system file &SYSFILE to file &FNAM.

K167

System files SYSOUT und SYSLST successfully switched.

If the UTM application was started in a dialog then message K167 confirms the successful switching of the SYSLST files for all the application’s tasks. SYSOUT continues to be assigned to the terminals unchanged.

 

K175

File &FNAM created

K184

There is already an Online Import or a run of KDCUPD active for the old KDCFILE.