This list can be handled in exactly the same way as a UTM object list (see Object lists).
The list contains the following columns:
Column | Meaning | |
---|---|---|
1st column without title | Selection of up to ten statistic collectors for the graphical display. You select a collector for graphical display by checking the corresponding box. Once the list has been refreshed, the collector list can be sorted on the selected collectors. Instead of a filter, the number of currently selected collectors is displayed. | |
Type | Icon and type of the statistic collector, as well as a specification of the unit of measurement (# for number, % for percent). | |
Collector is inactive. It can be activated via its property dialog. | ||
Collector sleeping (see 'State' column). | ||
Collector is active. | ||
Collector is active and is currently requesting a statistics value. | ||
Active collector in which the last collected statistics value exceeded the defined upper threshold. | ||
Active collector in which the last collected statistics value exceeded the defined lower threshold. | ||
Active collector whose assigned "collecting" object does not exist (no longer exists) in the corresponding UTM application. | ||
Active collector in which the last attempt to collect a statistics value failed. | ||
Object Type | Type and name of the "collecting" object that is assigned to the statistic collector. | |
Activated | Specifies whether the collector should collect statistic values. | |
Interval | Specifies the period between two pollings of statistic values. | |
Automatic Wake-Up | Specifies whether the sleeping collector should be woken up and start collecting data when the UTM application is available. Caution: If automatic wake-up is selected for one or more selectors for a UTM application then WebAdmin checks the availability of this UTM application at regular intervals. | |
State | State of the statistic collector. Possible values: 'Inactive': 'Active': 'Sleeping': 'without object': | |
Last Value | Indicates the last value or the smallest or largest value so far identified in the current WebAdmin session. '<.>' is displayed for each of these values until a successful polling operation has taken place. | |
Next Sample At | Specifies the time at which the statistic value will next be polled. '<.>' is displayed here until a polling operation has taken place. | |
Number of All Values | Specifies the number of all available values. | |
Values | Specifies the number of statistic values for the collector polled in the current WebAdmin session. | |
Upper Threshold | Upper threshold set for the collector or '<none>' if no upper threshold is defined. | |
Lower Threshold | Lower threshold set for the collector or '<none>' if no lower threshold is defined. | |
Upper threshold exceeded | Specifies whether the last polled value exceeds any upper threshold that may have been defined. | |
Lower threshold exceeded | Specifies whether the last polled value exceeds any lower threshold that may have been defined. | |
threshold exceeded | Specifies whether the last polled value exceeds any lower or upper threshold that may have been defined. | |
Upper Threshold Alert | Type of alert issued if the upper threshold is exceeded. | |
Lower Threshold Alert | Type of alert issued if the lower threshold is exceeded. | |
Remark | Comment concerning the statistic collector. | |
Statistic Values Lifetime | Limits the volume of collected statistic values stored in the configuration database. Possible values: 'Don't Save': 'Delete on Demand': 'Keep Last <n>': 'Keep 1 day/2 days/1 week/1 month': 'Current Application Run': | |
Automatic Export | Defines whether the values collected by this statistics collector should be automatically exported to a file. | |
Application | For an overview of all applications of a collection only: | |
Host | For UTM cluster applications: For an overview of all applications in a collection: Not displayed for standalone applications. |