ROBAR-CL on a BS2000 system consists of the DCAM application ROBAR-CL-DCAM and the user program ROBAR-CL-SDF, which are operated separately.
Starting ROBAR-CL-DCAM
Configure ROBAR-CL before starting ROBAR-CL-DCAM for the first time, see section "Configuring ROBAR-CL". Also ensure by means of the SHOW-MESSAGE-SUPPRESSION command that output of the messages NBR0740 and EXC0031 is not suppressed (by means of the SET-MESSAGE-SUPPRESSION command).
ROBAR-CL-DCAM is started by means of the SYSPRC.ROBAR-CL.<ver> start procedure (see "Modifying the start file for ROBAR-CL-DCAM") using /ENTER-PROCEDURE or /CALL-PROCEDURE.
Start ROBAR-CL-DCAM on every BS2000 system that wants to communicate with ROBAR-SV (and therefore with an archive system).
If a BS2000 system is to work with several ROBAR-SV instances (and therefore with several archive systems), ROBAR-CL-DCAM must be started the corresponding number of times.
You can monitor the status of the connection between ROBAR-CL-DCAM and ROBAR-SV by means of a job variable which you can define in the ROBAR-CL-DCAM start procedure (JV-NAME parameter). The job variable indicates whether the connection between the BS2000 system and ROBAR-SV is functioning or whether it has been interrupted. The precise content of the job variable is contained in the installation file SYSPAR.ROBAR-CL.<ver>.TEXT.D or E, see "Installing ROBAR-CL". This function is available if you are using the JV software product (see the “Job Variables” manual [7]).
If you are using MAREN, you must start the start procedure in an environment in which the MARENADM program can also run. This means in particular that
Disclose the MAREN password in the start procedure (see "Modifying the start file for ROBAR-CL-DCAM").
The user ID under which the start procedure is started must be able to access the MAREN syntax files.
The user ID under which the start procedure is started must have the system privilege
TAPE-ADMINISTRATIONif the software product SECOS is in use.
Terminating ROBAR-CL-DCAM
You should terminate the ROBAR-CL-DCAM application that was started via the ENTER job by entering the /BCAPPL command (see the “BCAM” manual [1]):
/BCAPPL APPLICATION=<application_name>
[,MODE=DEACTIVATE,TYPE=NORMAL,W=YES]
<application_name> was defined as parameter PARTNER in the start procedure, see "Modifying the start file for ROBAR-CL-DCAM".Starting ROBAR-CL-SDF
The ROBAR-CL-SDF user program is called via /START-ROBAR or /ROBAR.
Terminating ROBAR-CL-SDF
The ROBAR-CL-SDF user program is terminated with the statement END.