Calling SESCOSP

Sequence of commands for starting SESMON

/START-SESAM-TUNING-TRACE-EVAL

Starts SESCOSP with the start command START-SESAM-TUNING-TRACE-EVAL (see section “Starting SESAM/SQL programs via start commands”).


Example

SESCOSP is started by means of the procedure BEISP.START.COSP.

/CALL-PROCEDURE NAME=BEISP.START.COSP,PROCEDURE-PARAMETERS=NO,

/                    LOGGING=PARAMETERS(COMMANDS=YES,DATA=YES)


The input parameters are read in via an SDF screen. Since only the name of the CO-LOG file to be evaluated is specified, SESCOSP generates a report with the default settings.

/BEGIN-PROCEDURE LOGGING=ALL

/ASSIGN-SYSLST TO-FILE=LST.SESDBB.P.SESCOSP.K6

/ASSIGN-SYSDTA TO-FILE=*PRIMARY

/MOD-MSG-ATTRIBUTES TASK-LANGUAGE=D

/MODIFY-SDF-OPTIONS GUIDANCE=MAXIMUM

/START-SESAM-TUNING-TRACE-EVAL

PROGRAMM   : SESCOSP                     STATEMENT: CREATE-REPORT 
-----------------------------------------------------------------------------
INPUT-FILE           = SESAM.CO-LOG.70EX.0002
                       Filename_1..54_without-generation-version 
                       Input file, Standard: SESAM.CO-LOG.<TSN>.<NR> 
OUTPUT               = *SYSLST 
                       *SYSLST or filename_1..54_without-generation-version
                       Name of the output file 
SELECT               = *ALL 
                       *ALL or *PARAMETERS() 
                       Selection criteria for input 
REPORT-FORMAT        = *STD 
                       *STD or *PARAMETERS() 
                       Generic term for all selection criteria for the 
                       output 
-----------------------------------------------------------------------------
NEXT = *CONTINUE 
       *EXECUTE"F3" / + / Follow-up statement / *CONTINUE / *EXIT"K1" / 
       *EXIT-ALL"F1" / *TEST"F2" 
MESSAGE:  CMD0175 OTHER OPERATIONS DESIRED? PRESS *EXIT KEY 

//CREATE-REPORT INPUT-FILE=SESAM.CO-LOG.70EX.0002

/ASSIGN-SYSLST TO-FILE=*PRIMARY

/MODIFY-SDF-OPTIONS GUIDANCE=EXPERT

/END-PROCEDURE