The following BS2000 devices are predefined for the SU /390:
Type | MN | HC LUN | Details |
EMDISK | CCF0_CCF1 | 00 F0_F1 | 2 emulated disks (e.g. for BS2000 emergency system) |
KVP | C2_C3 | 00 C3_C4 | Name: HV0 |
LOCLAN | CC80_CC81 | 00 80_81 | Name: MANLO1 |
CDROM | T0 | 00 60 | Real CD-ROM drive |
EMFILE | T1 | 00 61 | emfile0061 |
In the case of MU redundancy on MU2 (MU index 2): | |||
EMDISK | CDF0_CDF1 | 00 F0_F1 | optional: 2 emulated disks (e.g. for BS2000 emergency system) |
KVP | C4_C5 | 00 C3_C4 | Name: HV0 |
LOCLAN | CD80_CD81 | 00 80_81 | Name: MANLO1 |
CDROM | TA | 00 60 | Real CD-ROM drive |
EMFILE | TB | 00 61 | emfile0061 |
Table 4: Predefined BS2000 devices on SU /390 (MU)
On the HNC the following BS2000 devices are predefined for the SU /390:
Type | MN | HC LUN | Details |
LOCLAN | - | - - | - |
ZASLAN | CC40_CC41 | 00 40_41 | Name: MCNPR |
In the case of HNC redundancy on HNC2: | |||
LOCLAN | - | - - | - |
ZASLAN | CD40_CD41 | 00 40_41 | Name: MCNPR |
Table 5: Predefined BS2000 devices on SU /390 (HNC)
In case of a Management Cluster, these BS2000 devices are predefined on MU and HNC for the SU /390 on both SE servers as described above.