POWER ON
Lights up green after the system power controller has completed the power-up sequence without error. In the standby status the indicator flashes.
SYSTEM
Lights up green when the CPU(s) is/are in operation.
CHECK
Lights up red when the SVP has detected a hardware malfunction or a fault in the power supply of the SU /390. In the event of a fault a buzzer sounds at the same time.
STATUS indicator
Depending on the POWER ON indicator, this indicator is switched on and displays details of the hardware status with a three-character alphanumeric display.
The display changes as sequences are executed. If the display finally stops at a particular value not equal to "000", this must be interpreted as the error code for a problem. In this case Customer Support should be contacted.
POWER ON | STATUS indicator | Hardware status |
Does not light up | Does not light up | Power failure |
Does not light up | b00 through bFF | Power supply units are being initialized. |
Flashing | Does not light up (in maintenance mode CE0) | Standby mode |
Lights up | 001 through 010 | Power-on sequence is active. |
Lights up | 100 through 399 | System is being initialized. |
Lights up | 000 | System initialization completed. |
Lights up | 500 through 599 | System stop initiated. |
Lights up | 010 through 001 | Power-off sequence is active. |
Lights up or does not light up (depending on the STATUS) | Begins with A | The entire /390 system (CPU box, AROMA, CHE boxes) or parts of it have been switched off because of a fault (power supply or operating temperature). Or an important function of the SVP has been stopped and a detailed error code cannot be displayed on the SVP console. |
Lights up | EEE | Another error has occurred. A detailed error code is displayed on the SVP console. |