Setting up PROGRAM LOAD FRAME PRESET1

In this example, you specify:

  • LOAD function 1 with the name AUTO (AUTO=Automatic Startup) for a POWER ON IPL

  • Device number of the IPL device to be used for a POWER ON IPL (currently A108)

  • Automatic IPL after a POWER ON

  • The LOAD FRAME should always be displayed as PROGRAM LOAD FRAME: DETAIL-1.


Requirement

You have opened the SVP window and set up the connection to the SVP console.

The MODE SELECTION FRAME is displayed on the screen (see "Selecting IORSF").


Invoke the AUXILIARY FRAME: LOAD PRESET1 screen

>

Enter AU in the FUNCTION=> field and then press the ENTER key,

or

>

enter the FR AU command in line 24 and press the ENTER key.

The AUXILIARY FRAME: MENU screen is displayed (see "Selecting IORSF").

>

Enter 5 in the SELECTION=> field. Press the ENTER key.

The AUXILIARY FRAME: LOAD PRESET1 screen is displayed:

                ----- AUXILIARY FRAME: LOAD PRESET1 -----     E90L01G
-START MODE-               -IPL DEVICE-
 ==> 1
 >1 START AUTO                1 PRESET GROUP -----------------+
 *2 START FAST                2 CURRENT GROUP --------+       |
 *3 START DIAL                3 UNIT ADDRESS -+       +       +
 *4 START                                     A108    A108    A108
                                                      XXXX    XXXX
                                                      XXXX    XXXX
                                                      XXXX    XXXX
 
                                                             -POWER ON IPL-
                                                               ==> 1
                                                               *1 ENABLE
                                                               >2 DISABLE
-INITIAL FRAME-
  ==> 2
  *1 LOAD FRAME(BASIC)                       *PF12 CATALOG
  >2 LOAD FRAME(DETAIL)                      *PF9 GO TO LOAD PRESET-2


               CL-0          CPU-0 CHP-0          RUN
 RA                                                          []-[]00

Figure 29: AUXILIARY FRAME: LOAD PRESET1 screen

You can reach this screen directly from the MODE SELECTION FRAME by entering the frame code AU5 in the FUNCTION=> field or the command FR AU5 in line 24 and pressing the ENTER key.

START MODE ==>

Enter 1 for automatic start of BS2000

IPL DEVICE


PRESET GROUP

A unit address from which the operating system is loaded (IPL) must be entered in the input field for PRESET GROUP.
A maximum of three further addresses can be entered. Entry in this example: A108.

POWER ON IPL ==>

Enter 1 for automatic IPL after POWER ON

INITIAL FRAME ==>

Enter 2 for a detailed display of the LOAD FRAME


Store parameters

>

Click on PF12

The values entered are saved and thus made known to the SVP. These settings are accessed for each IPL.