Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

Function of the displays

&pagelevel(4)&pagelevel

POWER ON

Lights up green after the system power controller has completed the power-up sequence without error. In the standby status the indicator flashes.

SYSTEM

Lights up green when the CPU(s) is/are in operation.

CHECK

Lights up red when the SVP has detected a hardware malfunction or a fault in the power supply of the SU /390. In the event of a fault a buzzer sounds at the same time.

STATUS indicator

Depending on the POWER ON indicator, this indicator is switched on and displays details of the hardware status with a three-character alphanumeric display.
The display changes as sequences are executed. If the display finally stops at a particular value not equal to "000", this must be interpreted as the error code for a problem. In this case Customer Support should be contacted.

POWER ON

STATUS indicator

Hardware status

Does not light up

Does not light up

Power failure

Does not light up

b00 through bFF

Power supply units are being initialized.

Flashing

Does not light up (in maintenance mode CE0)

Standby mode

Lights up

001 through 010

Power-on sequence is active.

Lights up

100 through 399

System is being initialized.

Lights up

000

System initialization completed.

Lights up

500 through 599

System stop initiated.

Lights up

010 through 001

Power-off sequence is active.

Lights up or does not light up (depending on the STATUS)

Begins with A

The entire /390 system (CPU box, AROMA, CHE boxes) or parts of it have been switched off because of a fault (power supply or operating temperature). Or an important function of the SVP has been stopped and a detailed error code cannot be displayed on the SVP console.

Lights up

EEE

Another error has occurred. A detailed error code is displayed on the SVP console.

Table 1: STATUS indicator