Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

(MA) MANUAL OPERATION FRAME

&pagelevel(4)&pagelevel

Figure 11: MANUAL OPERATION FRAME screen


By making an entry in this frame and pressing the ENTER key, you can perform various manual operations.

Instructions on this frame are only executed when the CPU has been stopped (see message in frame line 23). The CPU status is displayed in line 22.

>

Selection of a CPU by clicking on PF16

>

Stopping of the selected CPU (see (ML) MODE SELECTION FRAME "(ML) MODE SELECTION FRAME")

FUNCTION => 

The following function is executed after the corresponding character has been entered and the ENTER key has been pressed:

1

RATE CONTROL

defines program operation

2

ADRS COMPARE STOP3

sets mode for compare address stop

3

FIRM DUMP

outputs a firmware dump to tape, MTC or an emulated tape device (for Customer Support only)

4

HSA DUMP

executes HSA dump (for Customer Support only) (HSA Hardware/Software Area)

X

EXECUTE

executes functions 1 - 4

The following table shows the additional entries required for each of the four main functions in other input fields:


Input field

Function

RATE

CONTROL

ADRS

TYPE

ADRS

COMPSELECT

ADRS

SET

ADRS

COMPMODE

1 RATE CONTROL

o

x

x

x

x

2 ADRS COMP STOP

x

o

o

o

o

3 FIRM DUMP

x

x

x

x

x

4 HSA DUMP

x

x

x

x

x

o: entry required

x: entry not possible

RATE CONTROL =>

defines program operation

1

PROCESS

continual program operation

2

I-STEP

step-by-step command execution



ADRS TYPE =>

Entries for address compare stop:



entry under ADRS SET is

1

ABSOLUTE

absolute address

2

LOGICAL

a logical address



ADRS COMP SELECT =>

Address compare stop if compare stop address is same as

1

ANY

any address

2

OPERAND FETCH (OFETCH)

operand read address

3

OPERAND STORE (OSTORE)

operands write address

4

INSTRUCTION ADRS(IA)

instruction address

5

IA & OFETCH

instruction and operand read address

6

OFETCH & OSTORE

operand read and write address



ADRS SET =>

Compare stop address

XXXX

address space larger than 32 bits

XXXXXXXX

32-bit address



ADRS COMP MODE =>

Address compare stop mode

1

RESET

Switches off address compare stop and resets address compare stop conditions in the fields
ADRS TYPE, ADRS COMP SELECT and ADRS SET

2

SET

Switches on address compare stop

3

NORMAL

Switches off address compare stop



Changes in this frame are reserved for the Customer Support.