Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

Switching an Application Unit on/off

&pagelevel(3)&pagelevel

The Application Units are switched on and off individually or together with the other components of the SE server.

Information on switching on and starting the SE server and on switching it off and shutting it down is provided in the Basic Operating Manual [1], section "Switching the server on and off".

Other On/Off options

  • SE Manager
    As administrator or AU administrator logged-in to the SE Manager, in the Units table under Hardware -> Units click the Power off icon by the desired Application Unit.
    Further information can be found in the Quick Guide [7].
  • iRMC
    The iRMC offers various options for switching the Application Unit PY on and off, e.g. via the Power On Off page of the iRMC Web GUI.

    In the case of AU PQ, a Management Board is available instead of the iRMC. The AU can only be switched on/off at partition level.
  • Timed power-on/off
    You can configure a timed power-on/off on an AU PY with the help of the iRMC.

  • After power failure
    An Application Unit which is switched on reboots automatically following a power failure (depending on the settings in the BIOS setup or in the iRMC for AU PY resp. in the Management Board for AU PQ).

  • Power Button Override
    The Application Unit can be switched off by pressing and holding down the On/Off button (for approximately 4 - 5 seconds).

    CAUTION!
    There is a risk that data may be lost!
  • Wake up On LAN (WOL)

    An Application Unit is switched on by a command via the LAN (Magic Packet TM).