SHOW-CLONE-SESSION-STATUS Displays the status of clone pairs

Storage system:

ETERNUS DX/AF, Symmetrix/VMAX3

Domain:

DEVICE

Privileges:

TSOS, OPERATING, HW-MAINTENANCE,
SW-MONITOR-ADMINISTRATION,
HSMS-ADMINISTRATION

Routing code:

@


/SHOW-CLONE-SESSION-STATUS
provides information on the status of clone pairs in storage systems.

When device selection takes place, SHC-OSD automatically determines the correct volumes on the storage system concerned and then outputs the data which is relevant for the system. Only clone pairs of one storage system type can be selected (e.g. ETERNUS DX/AF or Symmetrix/VMAX3).

The command supports structured output to S variables (for further information, see the manual “Commands” [1]).

SHOW-CLONE-SESSION-STATUS

UNIT = *BY-VOLUME(...) / *BY-PUBSET(...) / *BY-SYMMETRIX(...) /




*BY-STORAGE(...) / list-poss(24): <alphanum-name 1..4 with-wildcards>


*BY-VOLUME(...)



|

VOLUME = list-poss(24): <vsn 1..6>


*BY-PUBSET(...)



|

PUBSET = list-poss(24): <cat-id 1..4>


*BY-SYMMETRIX(...)



|

SERIAL-NUMBER = <alphanum-name 3..12>



|

,LOGICAL-VOLUME = *ALL / <x-text 1..4>


*BY-STORAGE(...)



|

SERIAL-NUMBER = *ALL / <alphanum-name 3..14>



|

,LOGICAL-VOLUME = *ALL / <x-text 1..4>

,SELECT = *ALL-PRESEL ECTED / *BY-ATTRIBUTES(...)


*BY-ATTRIBUTES(...)



|

,REMOTE-COPY-USE = *STD / *TARGET-UNIT(...)



|


*TARGET-UNIT(...)



|



|

RA-GROUP = *UNIQUE / <integer 1..250>



|

,DEVICE = *ALL-PRESEL ECTED / *ALL-DEFINED / *ATTACHED / *DETACHED / *ANY

,UPDATE = *STD / NO / *DISCOVER

,CLONE-TYPE = *ANY / *COPY / *MIRROR
,INFORMATION = *STD / *CONTINUOUS-COPY


UNIT =

Selects the units by means of a particular VSN (*BY-VOLUME), a particular catalog ID (*BY-PUBSET), by means of the serial number and the internal number of the logical volume in the storage system (*BY-SYMMETRIX/*BY-STORAGE), or directly by means of the logical volume's mnemonic device name. At least one unit must be attached per emulated controller.

UNIT = *BY-VOLUME(...)
Selects the units by means of a particular VSN.

VOLUME = list-poss(24): <vsn 1..6>
Specifies the volume’s VSN.

UNIT = *BY-PUBSET(...)
Selects units by means of a pubset ID or volume set ID. Information is output for all volumes of the specified pubset. IDs of SF pubsets, volume sets or imported SM pubsets can be specified. No information is output for exported SM pubsets.

PUBSET = list-poss(24): <cat-id 1..4>
Specifies the pubset ID or volume set ID.

UNIT = *BY-SYMMETRIX(...)
Only relevant for Symmetrix/VMAX3.
Selects the unit by means of the serial number of the storage system and the internal number of the logical volume in the storage system.

SERIAL-NUMBER = <alphanum-name 3..12>
Specifies the serial number of the storage system (make sure it is unique!).

LOGICAL-VOLUME = *ALL
Selects all logical volumes of the storage system.

LOGICAL-VOLUME = <x-text 1..4>
Specifies the internal number of the logical volume in the storage system.


UNIT = *BY-STORAGE(...)
Only relevant for ETERNUS DX/AF.
Selects the unit by means of the serial number and the internal number of the logical volume in the storage system.

SERIAL-NUMBER = *ALL
All storage systems are selected.


All known clone pairs are output.
Processing this command can take some time if several storage systems exist.


SERIAL-NUMBER = <alphanum-name 3..14>
Specifies the serial number of the storage system (make sure it is unique!).

LOGICAL-VOLUME = *ALL
Selects all logical volumes of the storage system.

LOGICAL-VOLUME = <x-text 1..4>
Specifies the internal number of the logical volume in the storage system.

UNIT = list-poss(24): <alphanum-name 1..4 with-wildcards> 
Selects the unit by means of the mnemonic device name of the logical volume.


SELECT =

Selects the units by means of their remote copy use or their status as seen by BS2000.

SELECT = *ALL-PRESELECTED
The set of units is not restricted further. The global setting for SHC-OSD applies (value of DEVICE-PRESELECTION in the output of /SHOW-SHC-PROCESSING).

SELECT = *BY-ATTRIBUTES(...)
The set of units is restricted by means of selection criteria.

CLONE-TYPE=
Only relevant for ETERNUS DX/AF.
Specifies the clone type (and thus also the replication function) that is output.

CLONE-TYPE = *ANY
Information on all clone types is output.

CLONE-TYPE = *COPY
Information on the COPY clone type (and thus the QuickOPC replication function) is output.

CLONE-TYPE = *MIRROR
Information on the MIRROR clone type (and thus the EC replication function) is output.

REMOTE-COPY-USE =
Units with the specified remote copy use are selected.

REMOTE-COPY-USE = *STD
Outputs information on all units regardless of their remote copy use.

REMOTE-COPY-USE = *TARGET-UNIT(...)
Selects the clone pairs which are assigned to the target unit of a remote copy pair. The relevant source unit is specified in the UNIT operand.
For ETERNUS DX/AF the selection can only be made if the target unit is unique. Concurrent remote copy is not supported in the output.

RA-GROUP =
Only relevant for Symmetrix/VMAX3.
Selects the target unit using the RA group in the case of concurrent target units.

RA-GROUP = *UNIQUE
Selects the one existing target unit.

RA-GROUP = <integer 1..250>
Selects the target units of the specified source RA group.

DEVICE =
Selects the units by means of their status as seen by BS2000.

DEVICE = *ALL-PRESELECTED
Selects all units corresponding to the global setting for the SHC-OSD subsystem (value of DEVICE-PRESELECT in the output of /SHOW-SHC-PROCESSING).

DEVICE = *ALL-DEFINED
Selects all units generated in BS2000.

DEVICE = *DETACHED
Selects units which are generated in BS2000 but detached.

DEVICE = *ATTACHED
Selects all units attached in BS2000.

DEVICE = *ANY
Selects all units of the storage system which was specified in the UNIT operand.


UPDATE =

Controls updating of the data provided.

UPDATE = *STD
The data is updated in SHC-OSD before the SHOW command is executed.

UPDATE = *NO
The SHOW command is executed without the data being updated in SHC-OSD.

UPDATE = *DISCOVER
Before executing the SHOW-command the data in the Storage Manager and in SHC-OSD is updated.


CLONE-TYPE =
just for ETERNUS DX/AF.
Determines the clone-typ (and with that, the replicationsfunction), that is displayed.

CLONE-TYPE = *ANY
Informationen about all clone-types is displayed.

CLONE-TYPE = *COPY

Informationen about clone-types COPY (and with that, the replicationsfunction QuickOPC) is displayed.

CLONE-TYPE = *MIRROR

Informationen about clone-types MIRROR (and with that, the replicationsfunction EC) is displayed.


INFORMATION =
just for ETERNUS DX/AF.
The Operand INFORMATION is just relevant for the clone-type COPY in combination with the usage of the continuous copy function.

INFORMATION = *STD

The Output in old format is displayed.

INFORMATION = *CONTINUOUS-COPY

The output contains extended continuous copy information


Examples

/SHOW-CLONE-SESSION-STATUS UNIT=*BY-PUBSET(PUBSET=BT10)
/SHOW-CLONE-SESSION-STATUS UNIT=*BY-STOR(SERIAL-NUM=1003,LOGICAL-VOLUME=100)
/SHOW-CLONE-SESSION-STATUS  UNIT=*BY-SYMM(SERIAL-NUM=227,
      LOGICAL-VOLUME=100),REMOTE-COPY-USE=*TARGET-UNIT(RA-GROUP=*UNIQUE)
/SHOW-CLONE-SESSION-STATUS UNIT=5244

Output for clone pairs

The layout of the SYSOUT output differs because not all output fields are supplied with values by all storage systems. SHC-OSD automatically selects the correct output format. 

Outputs for ETERNUS DX/AF

 /SHOW-CLONE-SESSION-STATUS UNIT=*BY-STORAGE(SERIAL-NUMBER=7022)

 %  -----------------------------------------------------------------------------
 %  UNIT       VOLUME!             !             !SERIAL-NO             LOG-VOL
 %  -----------------------------------------------------------------------------
 %       CLON- VOLUME!STATE        !ACTIVE-FOR   !TYPE     CONT-  PERCENT-
 %       UNITS       !             !DDDD.HH:MM:SS!         COPY   COPIED
 %  =============================================================================
 %   4609            !             !             !    4621637022        00009
 %        460A       !SYNCHRONIZED !      -      ! MIRROR    -    100 % 0000A
 %  -----------------------------------------------------------------------------
 %   4610            !             !             !    4621637022        00010
 %        4611       !SYNCHRONIZED !      -      ! MIRROR    -    100 % 00011
 %  -----------------------------------------------------------------------------
 %   4612            !             !             !    4621637022        00012
 %        4613       !SPLIT        !  96.02:02:03! COPY      -    100 % 00013
 %  -----------------------------------------------------------------------------% 
 /SHOW-CLONE-SESSION-STATUS UNIT=4D80
  
 %  -----------------------------------------------------------------------------
 %  UNIT       VOLUME!             !             !SERIAL-NO             LOG-VOL
 %  -----------------------------------------------------------------------------
 %       CLON- VOLUME!STATE        !ACTIVE-FOR   !TYPE     CONT-  PERCENT-
 %       UNITS       !             !DDDD.HH:MM:SS!         COPY   COPIED
 %  =============================================================================
 %   4D80      TOBI.0!             !             !    4621637022        002AC
 %        4D82 TOBI.0!SPLIT        !   0.00:20:50! COPY      Y    100 % 002AE
 %  -----------------------------------------------------------------------------
/SHOW-CLONE-SESSION-STATUS UNIT=4DC0,INFORMATION=*CONTINUOUS-COPY               

%  -----------------------------------------------------------------------------
%                   !           PRIMARY           !          SECONDARY          
%  UNIT       VOLUME!LOG-VOL    SERIAL-NO  MODE   !LOG-VOL    SERIAL-NO  MODE   
%                   !           CLUSTER-NAME      !           PHASE      STATUS 
%  -----------------------------------------------------------------------------
%       CLONE VOLUME!   LOG-VOL STATE      %COPIED!   LOG-VOL STATE      %COPIED
%  -----------------------------------------------------------------------------
%                   !           ACTIVE-FOR        !           ACTIVE-FOR        
%  =============================================================================
%   4DC0      T2H1.0!002BC      4621637022 ACTIVE !00228      4631508013 STANDBY
%                   !           AF_DX8_02         !           NORMAL     NORMAL 
%        4DC6 T2HC.0!     002C2 SPLIT          51%!     0022E SPLIT          51%
%                   !            167.00:28:21     !            167.00:28:21     
%        4DC4 T2HB.0!     002C0 SPLIT          52%!     0022C SPLIT          52%
%                   !            167.00:47:52     !            167.00:47:53     
%  -----------------------------------------------------------------------------

Outputs for Symmetrix/VMAX3


/SHOW-CLONE-SESSION-STATUS UNIT=*BY-SYMMETRIX(SERIAL-NUMBER=207) 

 %  -----------------------------------------------------------------------------
 %  UNIT       VOLUME!             !            !SERIAL-NO             LOG-VOL
 %  -----------------------------------------------------------------------------
 %       CLON- VOLUME!STATE        !ACTIVE-FOR  !INDIRECT SIZE   PERCENT-  BACK/ 
 %       UNITS       !             !DDD.HH:MM:SS!UNIT    CLONE   COPIED     DIFF 
 % ==============================================================================
 %   260A            !             !            !000190100207          0004D
 %        26D2       !CREATED      !     -      !7734 MB 7734 MB   0 % 0016F Y/Y 
 %  -----------------------------------------------------------------------------
 %   260B            !             !            !000190100207          0004E
 %        26D3       !CREATED      !     -      !7734 MB 7734 MB   0 % 00170 Y/Y 
 %  -----------------------------------------------------------------------------
 %   260C            !             !            !000190100207          0004F
 %        26D4       !CREATED      !     -      !7734 MB 7734 MB   0 % 00171 Y/Y 
 %  -----------------------------------------------------------------------------
 %   260D            !             !            !000190100207          00050
 %        26D5       !PRECOPY      !     -      !   0 MB    0 MB 100 % 00172 Y/N 
 %  -----------------------------------------------------------------------------
 %   260E            !             !            !000190100207          00051
 %        26D6       !PRECOPY      !     -      !   0 MB    0 MB 100 % 00173 Y/N 
 %  -----------------------------------------------------------------------------
 %   2804            !             !            !000190100207          002DD
 %        2807       !RECREATED    !     -      !   0 MB    0 MB 100 % 002E0 Y/Y 
 %        2806       !RECREATED    !     -      !   1 MB    1 MB  99 % 002DF Y/Y 
 %        2805       !COPIED       !176.23:57:25!   0 MB    0 MB 100 % 002DE Y/Y 
 %  -----------------------------------------------------------------------------
 %   28E1            !             !            !000190100207          0041A
 %        28E8       !CREATED      !     -      !3984 MB 3984 MB   0 % 00421 Y/Y 
 %        28E7       !CREATED      !     -      !3984 MB 3984 MB   0 % 00420 Y/Y 
 %        28E3       !CREATED      !     -      !3984 MB 3984 MB   0 % 0041C Y/Y 
 %        28E2       !CREATED      !     -      !3984 MB 3984 MB   0 % 0041B Y/Y 
 %  -----------------------------------------------------------------------------

Meaning of the output columns (in alphabetical order)

Keyword                    

Meaning

with INF=

ACTIVE-FOR

Time since activation (/ACTIVATE-CLONE), format: DDD.HH:MM:SS. The ACTIVE-FOR value displays the time between the current BS2000 time and the timestamp in the storage system, when the clone has been synchronized. To display the correct value for ACTIVE-FOR the time of BS2000 and the storage system must be synchronous.

*STD
*CONT-C

BACK

Setting of the clone pair for copying in the background (Symmetrix/VMAX3 only)

Y

Copies the entire unit in the background

N

Does not copy the entire unit in the background

*STD
CLONEsee CLONE-UNITS*CONT-C

CLONE UNITS

MN of a clone unit or internal number of the logical volume in the storage system (5-character if the 1st character is not 0 (VMAX3) or with prefix #)

*STD
CLUSTER-NAMEName of the storage cluster*CONT-C

CONT-COPY

Using the Continuous Copy function for the volume

Y

Function is used

Function is not used

*STD

DIFF

Setting of the clone pair for the DIFFERENTIAL operand (option for reconstruction and restart of the clone session)
(Symmetrix/VMAX3 only)

Y

Reconstruction and restart of the clone session are possible

N

Reconstruction and restart of the clone session are not possible

*STD

INDIRECT SIZE
UNIT CLONE

Still unchanged on the unit concerned / for the particular status (in MB or GB)
(Symmetrix/VMAX3 only)

*STD

LOG-VOL

Internal number of the logical volume in the storage system

*STD
*CONT-C
MODE

Operating status of the primary or secondary storage system in the storage cluster

ACTIVEActive storage system
STANDBYStandby storage system
NONENo operating status
UNKNOWNUnknown operating status
*CONT-C

PERCENT-COPIED

Copied or remaining data volume in percent. Clone units can be completely copied and still show 99%, due to a short assignement by BS2000 during the seperation of original and clone unit.

*STD
PHASE

Operating status of the storage cluster

NORMAL

synchronized operating

DISABLED

Cluster deactivated

INITIALIZED

Cluster initialized, no volumes

MAINTENANCE

clone sessions are beeing cleaned

FAILED

Synchronisation not possible

FAILED-OVER

Failover executed

COPYING

Synchronisation for secondary storage system running

COPYING-BACK

Synchronisation for primary storage system running

FAILBACK-READY

Ready for failback

FAILED-BACK

failback executed

UNKNOWN

network problem

*CONT-C

SERIAL-NO

Serial number of the storage system

*STD
*CONT-C

STATE

Device status.

CREAT-IN-PROG

Clone unit is being connected to a unit to form a clone pair, no separate processing (Symmetrix/VMAX3 only)

CREATED

Clone unit is connected to a unit but not yet activated, no separate processing (Symmetrix/VMAX3 only)

COPY-ON-ACCES

Clone session is activated, the clone unit is READY, separate processing (Symmetrix/VMAX3 only)

COPY-IN-PROG

Clone session is activated, the clone unit is READY, separate processing, the unit is copied onto the clone unit in the background (Symmetrix/VMAX3 only)

COPIED

Clone session is activated, the clone unit is READY, separate processing, the clone unit is a complete copy (Symmetrix/VMAX3 only)

RECREATED

Clone unit is connected to a unit but not yet activated, no separate processing (Symmetrix/VMAX3 only)

REST-IN-PROG

Unit being reconstructed from the clone unit, data will be copied from the clone unit to the unit, no separate processing (Symmetrix only)
(only ETERNUS DX/AF with QuickOPC and Symmetrix/VMAX3)

RESTORED
PRECOPY

Unit has been reconstructed (Symmetrix/VMAX3 only)
Clone unit is connected to a unit but not yet activated, however, the unit is already being copied to the clone unit, no separate processing (Symmetrix/VMAX3 only)

SPLIT

Clone unit is connected to a unit n and is READY, separate processing

SYNCHRONIZING

Unit is copied to clone unit, the clone unit is NOT-READY, no separate processing (ETERNUS DX/AF only)

SYNCHRONIZED

The clone pair is synchronized, the clone unit is NOT-READY, no separate processing (ETERNUS DX/AF with EC only)

TERM-IN-PROG

The clone pair is being canceled, no separate processing (Symmetrix/VMAX3 only)

FAILED

Error state

*STD
*CONT-C
STATUS

Status des Storage Clusters

NORMAL

Normal operating

DISABLED

Deactivated

HALT

Error in storage cluster, see HALT-FACTOR

UNKNOWN

Unknown

*CONT-C

TYPE

Selected clone type (and thus also the replication function)

COPY

complete copy (QuickOPC)

MIRROR

mirrored copy (EC)

*STD

UNIT

MN of a unit or internal number of the logical volume in the storage system (5-character if the 1st character is not 0 (VMAX3) or with prefix #).

*STD

*CONT-C

VOLUME

VSN of a unit

*STD

*CONT-C

%COPIEDcopied data amount in percent*CONT-C

S variables

The S variables are identical for all storage systems; not all values are necessarily supplied.

Output information

Name of the S variable                        

T

Contents                         

Condition

INF=

Period since a clone unit was activated, format DDDD.HH:MM:SS without leading zeros

var(*LIST).CLONE-UNIT(*LIST).ACTIVE-FOR

S

''
<c-string 13..13>

*STD

Setting for copying in the background (Symmetrix/VMAX3)

var(*LIST).CLONE-UNIT(*LIST).BACKG-COPY

S

Y
N

*STD

Unchanged data on the clone unit during the  *COPY-ON-ACCESS status or data that is still to be restored (in MB) (Symmetrix/VMAX3)

var(*LIST).CLONE-UNIT(*LIST).CLONE-INDIRECT-SIZE

I

<integer 0..268435456>

*STD

Selected clone type (and replication function)
COPY: complete copy (QuickOPC)
MIRROR: mirrored copy (EC)

var(*LIST).CLONE-UNIT(*LIST).CLONE-TYPE

S

COPY
MIRROR

*STD

Using the Continuous Copy function for the volume

var(*LIST).CLONE-UNIT(*LIST).CONTINUOUS-COPY

S

''
Y

*STD

Setting for reconstruction and restart
(DIFFERENTIAL) (Symmetrix/VMAX3)

var(*LIST).CLONE-UNIT(*LIST).DIFFERENTIAL

S

Y
N

*STD

Internal number of the logical volume

var(*LIST).CLONE-UNIT(*LIST).LOGIC-VOL

S

''
<c-string 1..5>

*STD

Data copied to the clone unit in percent

var(*LIST).CLONE-UNIT(*LIST).PERCENT-COPIED

I

<Integer 0..100>

*STD

First copy process after the start of the clone session has been completed, unit has been copied in full onto the clone unit (does not mean that the clone pair is synchronous) (Symmetrix/VMAX3)

var(*LIST).CLONE-UNIT(*LIST).PRECOPIED

S

Y
N
''

*STD
Timestamp since a clone unit in primary storage system with fromat DDDD.HH:MM:SS without leading zeros was activated.var(*LIST).CLONE-UNIT(*LIST).PRIMARY.ACTIVE-FORS''
<c-string 13..13>
*CONT-C
Internal number of a logical volumevar(*LIST).CLONE-UNIT(*LIST).PRIMARY.LOGIC-VOLS''
<c-string 1..5>
*CONT-C
copied data on the clone unit in the primary storage system in percentvar(*LIST).CLONE-UNIT(*LIST).PRIMARY.PERCENT-COPIEDI<Integer 0..100>*CONT-C
Device status of a clone-unit on primary storage system
(see INF=*STD)
var(*LIST).CLONE-UNIT(*LIST).PRIMARY.STAS*RESTORE-IN-PROGRESS
*SPLIT
*SYNCHRONIZING
*SYNCHRONIZED
*FAILED
*CONT-C
Timestamp since a clone unit in secondary storage system with fromat DDDD.HH:MM:SS without leading zeros was activated.var(*LIST).CLONE-UNIT(*LIST).SECONDARY.ACTIVE-FORS''
<c-string 13..13>
*CONT-C
Internal number of a logical volumevar(*LIST).CLONE-UNIT(*LIST).SECONDARY.LOGIC-VOLS''
<c-string 1..5>
*CONT-C
copied data on the clone unit in the secondary storage system in percentvar(*LIST).CLONE-UNIT(*LIST).SECONDARY.PERCENT-COPIEDI<Integer 0..100>*CONT-C
Device status of a clone-unit on secondary storage system
(see INF=*STD)
var(*LIST).CLONE-UNIT(*LIST).SECONDARY.STAS*RESTORE-IN-PROGRESS
*SPLIT
*SYNCHRONIZING
*SYNCHRONIZED
*FAILED
*CONT-C

Device status of a clone unit
*CREATE-IN-PROGRESS: Clone pair being created (Symmetrix/VMAX3)
*CREATED: Clone pair created (Symmetrix/VMAX3)
*COPY-ON-ACCESS: Clone pair activated, separate processing (Symmetrix/VMAX3)
*COPY-IN-PROGRESS: Clone pair activated, separate processing (Symmetrix/VMAX3)
*COPIED: Clone pair activated, separate processing (Symmetrix/VMAX3)
*RECREATED: Clone pair created again (Symmetrix/VMAX3)
*RESTORE-IN-PROGRESS: Copying from the clone unit to the unit (after /RESTORE-FROM-CLONE) (ETERNUS DX/AF with QuickOPC, Symmetrix/VMAX3)
*RESTORED: Reconstruction of the unit from the clone unit completed (Symmetrix/VMAX3)
*TERM-IN-PROGRESS: Clone pair being canceled (Symmetrix/VMAX3)
*PRECOPY: Clone pair created, unit already being copied to clone unit (Symmetrix/VMAX3)
*SPLIT: Clone pair being separated after reconstruction
*SYNCHRONIZING: Unit is being copied to clone unit (ETERNUS DX/AF)
*SYNCHRONIZED: Clone pair is synchronized (ETERNUS DX/AF with EC)
*FAILED: Error state

var(*LIST).CLONE-UNIT(*LIST).STA

S

*CREATE-IN-PROGRESS
*CREATED
*COPY-ON-ACCESS
*COPY-IN-PROGRESS
*COPIED
*RECREATED
*RESTORE-IN-PROGRESS
*RESTORED
*TERM-IN-PROGRESS
*PRECOPY
*SPLIT
*SYNCHRONIZING
*SYNCHRONIZED
*FAILED

*STD

MN of a clone unit

var(*LIST).CLONE-UNIT(*LIST).UNIT

S

''
<mnemo-name>

*STD
*CONT-C

Unchanged data on the unit (in MB) (Symmetrix/VMAX3)

var(*LIST).CLONE-UNIT(*LIST).UNIT-PROTECTED-SIZE

I

<integer 0..268435456>

*STD

VSN of a clone unit

var(*LIST).CLONE-UNIT(*LIST).VOL

S

''
<vsn>

*STD
*CONT-C
Name of the storage clustervar(*LIST).CLUSTER-NAMES<c-string 0..16>*CONT-C

Operating status of the Storage Cluster
*NORMAL: Synchronous operation
*DISABLED: Cluster disabled
*INITIALIZED: Cluster initialized but no volumes yet
*MAINTENANCE: Clone sessions are cleared
*FAILED: Synchronization not possible
*FAILED-OVER: Failover executed
*COPYING: Synchronization to secondary storage system in progress
*COPYING BACK: Synchronization to primary storage system in progress
*FAILBACK-READY: Ready for failback
*FAILED-BACK: Failback executed
*UNKNOWN: Network problem

var(*LIST).CLUSTER-PHASES

*NORMAL
*DISABLED
*INITIALIZED
*MAINTENANCE
*FAILED
*FAILED-OVER
*COPYING
*COPYING-BACK
*FAILBACK-READY
*FAILED-BACK
*UNKNOWN

*CONT-C

Operating status of the primary storage system
*ACTIVE: Active storage system
*STANDBY: Standby storage system
*NONE: No operating status
*UNKNOWN: Unknown operating status

var(*LIST).CLUSTER-STATUSS*NORMAL
*DISABLED
*HALT
*UNKNOWN
*CONT-C

Number of assigned clone units

var(*LIST).NUM-OF-CLONE-UNITS

I

<integer 0..65535>


Operating status of the primary storage system
*ACTIVE: Active storage system
*STANDBY: Standby storage system
*NONE: No operating status
*UNKNOWN: Unknown operating status
var(*LIST).PRIMARY.MODES*ACTIVE
*STANDBY
*NONE
*UNKNOWN
*CONT-C
Serial number of the primary storage systemvar(*LIST).PRIMARY.SERIAL-NOS''
<c-string 3..14>
*CONT-C
Internal number of the volume in the primary storage systemvar(*LIST).PRIMARY.UNIT-LOGIC-VOLS''
<c-string 1..5>
*CONT-C
Operating status of the secondary storage system
*ACTIVE: Active storage system
*STANDBY: Standby storage system
*NONE: No operating status
*UNKNOWN: Unknown operating status
var(*LIST).SECONDARY.MODES*ACTIVE
*STANDBY
*NONE
*UNKNOWN
*CONT-C

Serial number of the secondary storage system

var(*LIST).SECONDARY.SERIAL-NOS''
<c-string 3..14>
*CONT-C
Internal number of the volume in the secondary storage systemvar(*LIST).SECONDARY.UNIT-LOGIC-VOLS''
<c-string 1..5>
*CONT-C

Serial number of the storage system

var(*LIST).SERIAL-NO

S

''
<c-string 3..14>

*STD

MN of a unit

var(*LIST).UNIT

S

''
<mnemo-name>

*STD
*CONT-C

Internal number of the logical volume

var(*LIST).UNIT-LOGIC-VOL

S

''
<c-string 1..5>

*STD

VSN of a unit

var(*LIST).UNIT-VOL

S

''
<vsn>

*STD
*CONT-C


Command return codes

(SC2)

SC1

Maincode

Meaning


0

CMD0001

Command executed successfully


1

CMD0202

Syntax error


32

NDE2002

Internal error


64

CMD0087

Function not permitted in the current input mode or with the current task privileges


64

CMD0216

Required privilege not available


64

NDE1000

Device not found or not in the storage system


64

NDE1001

Device not attached


64

NDE1002

Controller not found


64

NDE1003

Data medium not online or not unique


64

NDE1004

Pubset not found or wrong pubset type


64

NDE1010

Enginuity version is not supported (too low)


64

NDE1043

Pubset type not supported


64

NDE1100

Invalid pubset state


64

NDE1114

Serial number not found


64

NDE1115

Serial number not unique


64

NDE1116

Storage system’s logical volume not found


64

NDE1119

No target unit found


64

NDE1125

Initialization of storage system information running


64

NDE1126

Device unknown or storage system not supported


64

NDE1127

Device of a storage system is not supported


64

NDE1128

At least one unit from system is not Symmetrix/VMAX3


64

NDE1150

No gatekeeper device found


64

NDE1800

Device not found or not in the storage system


64

NDE1810

Storage system’s operating system version not supported


64

NDE1814

Storage system’s serial number not found


64

NDE1815

Storage system’s serial number not unique


64

NDE1816

Storage system’s logical volume not found


64

NDE1890

Management instance not found


64

NDE1702

Connection to SYMAPI server aborted


64

NDE2000

Execution partially successful


64

NDE2001

Command not executed


64

NDE2006

No output information available


64

NDE2011

Symmetrix license not entered


130

NDE1082

Memory bottleneck during processing of command