Source/target unit as TimeFinder/Clone unit

If a TimeFinder/Clone unit is also an SRDF source unit, the following constraints apply:

  • The clone session can be aborted at any time (using /STOP-CLONE-SESSION).

  • All other TimeFinder/Clone functions are by default possible only in the remote copy status IN-HOLD or ERROR with an accessible clone unit (status: READY).

  • If the SRDF connection is in the remote copy status ACTIVE or ERROR and the clone unit is in the NOT-READY status, the clone functions can be executed with FORCE=*YES.

If a TimeFinder/Clone unit is also an SRDF target unit, the following constraints apply:

  • The clone session can be aborted at any time (using /STOP-CLONE-SESSION).

  • All other TimeFinder/Clone functions are possible only in the remote copy status IN-HOLD or ERROR and in the case of /SET-REMOTE-COPY-ACCESS with TARGET-ACCESS=*DIRECT.

  • The processing mode (copy mode) must be SYNCH.

  • The SRDF source unit and SRDF target units have the same capacity.

  • The clone unit cannot be activated (/ACTIVATE-CLONE) for the duration of the SRDF copy processes.