Settings for remote copy mode are specified using the remote copy parameters. The remote copy parameters are COPY-MODE
, ON-ERROR
and PENDING-UPDATES
.
You can set the COPY-MODE
and ON-ERROR
remote copy parameters using the /MODIFY-REMOTE-COPY-PARAMETER
command. The PENDING-UPDATES
parameter is always set on the storage system with the target unit. If an error occurs, the ON-ERROR
and PENDING-UPDATES
remote copy parameters have a considerable impact on the availability of the source and target units (see section "ON-ERROR" and section "PENDING-UPDATES").
/SHOW-REMOTE-COPY-STATUS
displays the values of the ON-ERROR
parameter in a separate column. The internal storage system parameter PENDING-UPDATES
is displayed in the two-part column PEND-UPD-ON-TARGET
. The ALLOW
column indicates whether or not PENDING-UPDATES
are permitted. The CURR-SIZE
column indicates the current size of outstanding writes to the target unit.
/SHOW-REMOTE-COPY-STATUS UNIT=(587C,587D),INF=*PARAMETERS % -------------------------------------------------------------------------- % SRC TAR VOLUME!COPY-MODE: !ON- !PEND-UPD-ON-TARG: % UNIT UNIT !MODE WR-BUFF P-UPD-LIM!ERROR !ALLOW CURR-SIZE % ========================================================================== % 587C #007C 8BN4.0!SYNCH - - !CONTI !NO 0 MB % 587D #007D 8BN4.1!SYNCH - - !CONTI !NO 0 MB