Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

ACTIVATE-CLONE Activates a clone pair

&pagelevel(3)&pagelevel

Storage system:

ETERNUS DX/AF

Domain:

DEVICE

Privileges:

TSOS


/ACTIVATE-CLONE
activates one or more clone pairs, each of which consists of one original unit and one clone unit. Following successful activation, the original unit and the clone unit are split: Both can be accessed from the host by applications. From the application’s viewpoint, the clone unit contains all the data of the original unit at command processing time.

The original units of the clone pairs are specified in the UNIT operand.

When the original units are selected via a pubset (UNIT=*BY-PUBSET), clone units must exist for all units of the pubset. The clone pubset on the clone units can be renamed directly using the NEW-PUBSET operand if an SF pubset is involved.

The CLONE-UNIT operand enables the clone unit which is to be activated to be selected if several pairs in the CREATED status exist for an original unit. By default the first clone unit is activated.

The file consistency over multiple volumes must be ensured by the caller. For this purpose a synchronization point should be created for the data before the command is called, see section "Activating clone pairs".

SHC-OSD checks the global and task-specific security settings before this command is executed (see "Security settings of SHC-OSD"). The current security settings can be displayed with /SHOW-SHC-PROCESSING (see also "SHOW-SHC-PROCESSING Displays settings of SHC-OSD"). They can be changed in the SHC-OSD parameter file (see "Configuration of SHC-OSD") for the next time SHC-OSD is started or with /MODIFY-SHC-PROCESSING for ongoing operations (see "MODIFY-SHC-PROCESSING Changes settings of SHC-OSD").

For QuickOPC clone

The command is not required for this function and therefore rejected.

For EC clones

The command is executed only if the clone pair has the SYNCHRONIZED status.

The CLONE-UNIT operand enables the clone unit which is to be activated to be selected if multiple pairs in the SYNCHRONIZED status exist for an original unit.
By default the first possible clone unit is activated.

When the REC function is used, the original unit can also be the source unit of a remote copy pair. The target unit can also be the original unit of a clone pair. In this case the source unit is specified in the UNIT operand, and the clone pair on the target unit is selected using the SELECT=*TARGET-UNIT operand. No concurrent remote copy is supported in such a configuration.
After the clone pair has been activated, it assumes the SPLIT status.

ACTIVATE-CLONE

UNIT = *BY-VOLUME(...) / *BY-PUBSET(...) / *BY-STORAGE(...) /




list-poss(256): <alphanum-name 2..2> / <x-text 4..4>


*BY-VOLUME(...)



|

VOLUME = <vsn 1..6>


*BY-PUBSET(...)



|

PUBSET = <cat-id 1..4>



|

,NEW-PUBSET = *SAME / *SPECIAL-VSN / <cat-id 1..4>



|

,HOLD-IO = *NO / *UNTIL-ACTIVATED


*BY-STORAGE(...)



|

SERIAL-NUMBER = <alphanum-name 3..14>



|

,LOGICAL-VOLUME = <x-text 1..4>

,CLONE-UNIT = *FIRST-POSSIBLE / *FROM-SHOW-OUTPUT(...) /





*BY-STORAGE(...) / list-poss(256): <alphanum-name 2..2> / <x-text 4..4>


*FROM-SHOW-OUTPUT(...)



|

POSITION = *LAST / <integer 1..16>


*BY-STORAGE(...)



|

CLONE-LOGICAL-VOLUME = <x-text 1..4>

,SELECT = *STD / *TARGET-UNIT


UNIT =

Selects the units by means of a particular VSN (*BY-VOLUME), a particular catalog ID (*BY-PUBSET), by means of the serial number and the internal number of the logical volume in the storage system (*BY-STORAGE), or directly by means of the logical volume's mnemonic device name.

UNIT = *BY-VOLUME(...)
Selects the units by means of a particular VSN.

VOLUME = <vsn 1..6>
Specifies the volume’s VSN.

UNIT = *BY-PUBSET(...)
Selects units by means of a pubset ID or volume set ID. The pubset is protected against reconfiguration during command processing. When an SF pubset is selected, the volumes of the clone pubset can be renamed using NEW-PUBSET.

PUBSET = <cat-id 1..4>
Specifies the pubset ID or volume set ID. When HOLD-IO=*UNTIL-ACTIVATED, no volume set ID may be specified.

NEW-PUBSET =
Determines the catalog ID of the clone pubset.

NEW-PUBSET = *SAME
The clone pubset is not renamed, i.e. it retains the same name.

NEW-PUBSET = *SPECIAL-VSN
All volumes of an SF pubset’s clone units are automatically renamed to prevent confusion with the original. For this purpose the period in a VSN in point notation is changed to a colon (e.g. AA.001 to AA:001), or in PUB notation the PUB string is changed to P:B (e.g. PUBA01 to P:BA01).

NEW-PUBSET = <cat-id 1..4>
An SF pubset’s clone pubset is renamed by specifying the new catalog ID explicitly. The catalog ID can also differ in length from the PUBSET operand. The new clone pubset also becomes an SF pubset. An existing MRSCAT entry is used if it is of the correct type. If it is not, it is deleted and created again. See the notes in section "Renaming SF pubsets with SHC-OSD".

HOLD-IO =
Handles inputs/outputs on the clone pair during splitting (see “Consistent splitting of a pubset in the shared pubset network” in "Activating clone pairs").

HOLD-IO = *NO
The inputs/outputs on the clone pair are executed without any change. This can lead to data inconsistencies on the clone units for applications which are not suspended before splitting takes place.

HOLD-IO = *UNTIL-ACTIVATED
The inputs/outputs on the clone pair are suspended until all the imported pubset’s clone pairs are in the COPY-ON-ACCESS status. Subsequently inputs/outputs are resumed on the units. If an error occurs when inputs/outputs are suspended or resumed, the command is aborted. The input/output activity may need to be resumed using /RESUME-IO.

UNIT = *BY-STORAGE(...)
Selects the unit by means of the serial number and the internal number of the logical volume in the storage system.

SERIAL-NUMBER = <alphanum-name 3..14>
Specifies the serial number of the storage system (make sure it is unique!).

LOGICAL-VOLUME = <x-text 1..4>
Specifies the internal number of the logical volume in the storage system.

UNIT = list-poss(256): <alphanum-name 2..2> / <x-text 4..4>
Selects the unit by means of the mnemonic device name of the logical volume.


CLONE-UNIT =

Selects the clone unit. If more than one clone unit exists for a unit, a specific clone unit must be selected.

CLONE-UNIT = *FIRST-POSSIBLE
Selects the first possible clone unit for the command.

CLONE-UNIT = *FROM-SHOW-OUTPUT(...)
Selects the clone unit via its position in the output list of /SHOW-CLONE-SESSION-STATUS.

POSITION = *LAST
Selects the last clone unit in the output list.

POSITION = <integer 1..16>
Specifies the position of the clone unit.

CLONE-UNIT = *BY-STORAGE(...)
Selects the clone unit by means of the internal number of the logical volume in the storage system.

CLONE-LOGICAL-VOLUME = <x-text 1..4>
Specifies the internal number of the logical volume in the storage system.

CLONE-UNIT = list-poss(256): <alphanum-name 2..2> / <x-text 4..4>
Specifies the mnemonic device name of the logical volume.


SELECT =

Selects the clone pairs.

SELECT = *STD
Selects the clone pairs which were defined using the UNIT operand.

SELECT = *TARGET-UNIT
Selects the clone pairs which are assigned to the target unit of a remote copy pair. The relevant source unit is specified in the UNIT operand.
The selection can only be made if the target unit is unique. Concurrent remote copy is not supported here.


Command processing

Message NDE1073 is output to SYSOUT for each device and distributed via routing code 0, i.e. it is logged in the CONSLOG file only. You will find detailed information on the CONSLOG file (log file) in the “Introduction to System Administration” manual [5].

Examples

/ACTIVATE-CLONE UNIT=*BY-PUBSET(PUBSET=OLD,NEW-PUBSET=*SAME)
/ACTIVATE-CLONE UNIT=*BY-PUBSET(PUBSET=OLD,NEW-PUBSET=NEW, HOLD-IO=*UNTIL-ACTIVATED)

Command return codes

(SC2)

SC1

Maincode

Meaning


0

CMD0001

Command executed successfully

1

0

NDE2003

Command successfully executed, no processing necessary

2

0

NDE2004

Command successfully executed but not yet completed


1

CMD0202

Syntax error


1

NDE1036

PUBSET and NEW-PUBSET have different lengths


32

NDE2002

Internal error


64

CMD0087

Function not permitted in the current input mode or with the current task privileges


64

CMD0216

Required privilege not available


64

NDE1000

Device not found or not in the storage system


64

NDE1001

Device not attached


64

NDE1003

Data medium not online or not unique


64

NDE1004

Pubset not found or wrong pubset type


64

NDE1005

Pubset not homogeneous


64

NDE1008

Volume cannot be allocated


64

NDE1015

Device not defined in BS2000


64

NDE1043

Pubset type not supported


64

NDE1044

NEW-PUBSET already exists


64

NDE1057

Function not supported


64

NDE1087

HOLD-IO=*UNTIL-ACTIVATED permitted only for imported pubsets


64

NDE1100

Invalid pubset state


64

NDE1101

More than one sharer for pubset


64

NDE1102

Not all volumes could be allocated


64

NDE1103

No reconfiguration lock for pubset


64

NDE1104

HOLD-IO=*UNTIL-ACTIVATED: DAB caching active


64

NDE1105

Inconsistent pubset


64

NDE1108

SELECT=*TARGET-UNIT: UNIT is not a source unit


64

NDE1109

SELECT=*TARGET-UNIT: TARGET-UNIT not found


64

NDE1120

Error suspending or resuming input/output access to pubset


64

NDE1143

Error occurred during processing of mirror pair


64

NDE1171

Target unit is not unique


64

NDE1530

No clone function for the unit


64

NDE1531

Different number of devices in the unit and clone unit specifications


64

NDE1535

Device is a clone unit


64

NDE1540

Incorrect state of unit


64

NDE1541

Incorrect state of clone unit


64

NDE1548

Clone type cannot be determined clearly


64

NDE1549

No clone unit assigned for clone unit selection


64

NDE1553

Device is not a clone unit


64

NDE1584

Clone pair already activated


64

NDE1592

Clone pair already activated and clone unit renamed


64

NDE1596

Clone pair(s) already activated


64

NDE1800

Device not found or not in storage system


64

NDE1802

Error communicating with StorMan server


64

NDE1803

Management instance not available


64

NDE1810

Storage system’s operating system version not supported


64

NDE1811

Function not supported for storage system


64

NDE1812

StorMan server switched off by command


64

NDE1814

Storage system’s serial number not found


64

NDE1815

Storage system’s serial number not unique


64

NDE1816

Storage system’s logical volume not found


64

NDE1833

No suitable Storman server found


64

NDE1853

Storage unit locked


64

NDE1890

Management instance not found


64

NDE1899

Command not possible for current status of the mirror pair


64

NDE2000

Execution partially successful


64

NDE2001

Command not executed


64

NDE2009

Command aborted with K2 key


64

NDE2014

StorMan error in command


64

NDE2017

Command not possible for current status of the replication


130

NDE1082

Memory bottleneck during processing of command


130

NDE2005

Command cannot be executed at the moment