SHOW-STORAGE-CLUSTER-CONFIG Displays configurations of Storage Clusters

&pagelevel(3)&pagelevel

Storage system:

ETERNUS DX/AF

Domain:

DEVICE

Privileges:

TSOS, OPERATING, HW-MAINTENANCE,
SW-MONITOR-ADMINISTRATION,
HSMS-ADMINISTRATION

Routing code:

@


/SHOW-STORAGE-CLUSTER-CONFIG
provides information on the configuration and the status of the Storage Clusters in the ETERNUS DX/AF storage systems.

The command supports structured output to S variables (for further information, see the manual “Commands” [1]).

SHOW-STORAGE-CLUSTER-CONFIG

CLUSTER-NAME = *ALL / <posix-filename 3..16>

,INFORMATION = *STD / *VOLUMES


CLUSTER-NAME =

Selecting the Storage Cluster by its name or selecting all Storage Clusters (*ALL).

CLUSTER-NAME = *ALL
Output for all known Storage Clusters.

CLUSTER-NAME = <posix-filename 3..16>
Selecting the Storage Cluster by its name (see "Storage Cluster Option").

It can be abbreviated to three characters with wildcards. That means all storage clusters are displayed that contain the certain string.


INFORMATION =

Determines the output volume, see the examples for the command.

INFORMATION = *STD
Global information on the Storage Cluster is displayed.

INFORMATION = *VOLUMES
Information about the volume pairs of the Storage Cluster is displayed.

Examples

/SHOW-STORAGE-CLUSTER-CONFIG CLUSTER-NAME=*ALL,INFORMATION=*STD

 %  -----------------------------------------------------------------------------
 %  CLUSTER-NAME     PHASE          FAILOVER FAILBACK SPLIT!PRIMARY    SECONDARY
 %                   STATUS         HALT-FACTOR       #BS2V!MODE       MODE
 %  =============================================================================
 %  DX500_1-DX500_2  FAILBACK-READY MANUAL   MANUAL   WRITE!4621347002 4621349005
 %                   NORMAL         NONE                 0 !STANDBY    ACTIVE
 %  -----------------------------------------------------------------------------
 %  DX500_2-DX500_1  NORMAL         MANUAL   MANUAL   WRITE!4621349005 4621347002
 %                   NORMAL         NONE                10 !ACTIVE     STANDBY
/SHOW-STORAGE-CLUSTER-CONFIG CLUSTER-NAME=DX500_1-DX500_2,INFORMATION=*VOLUMES

 %  -----------------------------------------------------------------------------
 %   UNIT VOLUME!PRIM SEC !STORAGE-CLUSTER:
 %              !VOLUME   !NAME             STATUS  SYNC-STATE SYNC! CONT-COPY
 %  =============================================================================
 %    F2EE       !02EE 037C!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     YES
 %    F2EF       !02EF 037D!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     YES
 %    F2F0       !02F0 037E!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     YES
 %    F2F1       !02F1 037F!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     YES
 %   #02F2       !02F2 0380!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     NO
 %   #02F3       !02F3 0381!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     NO
 %   #02F4       !02F4 0382!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     NO
 %   #02F5       !02F5 0383!DX500_1-DX500_2 !ACTIVE  SYNC       100%!     NO
 %  -----------------------------------------------------------------------------

Meaning of the output columns (in alphabetical order)

Keyword                   

Meaning

with INF =

#BS2V

Number of BS2000 volumes in the storage cluster

*STD

CLUSTER-NAME

Name of the Storage Cluster

*STD

CONT-COPY

Using the Continuous Copy function for the volume

YES

Function is used

NO

Function is not used

*VOLUMES

FAILOVER

Failover mode set in the Storage Cluster

MANUAL

Manual mode

AUTOMATIC

Automatic mode

*STD

FAILBACK

Failback mode set in the Storage Cluster

MANUAL

Manual mode

AUTOMATIC

Automatic mode

*STD


HALT-FACTOR

Reason for error in the Storage Cluster

UNKNOWN

Unknown error

NONE

No error

GROUP-DISCONNECTED

Device path not available

WRONG-VERSION

Device or firmware not suitable for SCO

GROUP-SET-MISSING

Missing setting for device

GROUP-SET-MISMATCH

Data transfer cannot be executed

CL-CONTR-SRV-DISC

Cluster control server not connected

*STD

MODE

Operating status of the primary or secondary storage system in the Storage Cluster

ACTIVE

Active storage system

STANDBY

Standby storage system

NONE

No operating status

UNKNOWN

Unknown operating status

*STD

PHASE

Operating status of the Storage Cluster

NORMAL         

Synchronized operation

DISABLED

Cluster disabled

INITIALIZED

Cluster initialized but no volumes yet

MAINTENANCE

Clone sessions are cleared

FAILED

Synchronization not possible

FAILED-OVER

Failover executed

COPYING

Synchronization to secondary storage system in progress

COPYING-BACK

Synchronization to primary storage system in progress

FAILBACK-READY

Ready for failback

FAILED-BACK

Failback executed

UNKNOWN

Network problem

*STD

PRIM VOLUME

Internal number of the volume in the primary storage system

*VOLUMES

PRIMARY

Serial number of the primary storage system in the Storage Cluster

*STD

SEC VOLUME

Internal number of the volume in the secondary storage system

*VOLUMES

SECONDARY

Serial number of the secondary storage system in the Storage Cluster

*STD

SPLIT

Behavior in case the automatic REC connection from the active to the standby storage system is disconnected.

WRITE

The write process for the volume in the active storage system is continued. A data inconsistency to the volume in the standby storage system is created.

READ

The volume in the active storage system is only being used for read processes. Write processes are rejected.

*STD

STATUS

Status of the Storage Cluster

NORMAL

Normal operation

DISABLED

Disabled

HALT

Error in the Storage Cluster, see HALT-FACTOR

UNKNOWN

Unknown

*STD

STORAGE-CLUSTER:

NAME

Name of the Storage Cluster

*VOLUMES

STORAGE-CLUSTER:
STATUS

Remote copy status of the volumes in the Storage Cluster

ACTIVE

Remote copy mode active

IN-HOLD

Remote copy mode interrupted(/HOLD-REMOTE-COPY)

F-OVER

Remote-Copy-Betrieb unterbrochen (/FAILOVER-STORAGE-CLUSTER)

ERROR

Remote copy mode interrupted after an error

BROKEN

Unrecoverable error after failure

*VOLUMES

STORAGE-CLUSTER:
SYNC-STATE

Synchronization status of the volumes in the Storage Cluster

SYNC

Volumes are synchronized

SYNCING

Volumes are being synchronized

UNKNOWN

Unknown

*VOLUMES

STORAGE-CLUSTER:
SYNC

Synchronization progress of the volumes in the Storage Cluster (in percent)

*VOLUMES

UNIT

MN of the BS2000 volume (if configured)

*VOLUMES

VOLUME

VSN of the BS2000 volume (if readable)

*VOLUMES

S variables

Output information

Name of the S variable

T

Contents                       

Condition INF=

Name of the Storage Cluster

var(*LIST).STD.CLUSTER-NAME

S

''
<posix_filename 3..16>

*STD

Failback mode set in the Storage Cluster
*MANUAL: Manual mode
*AUTOMATIC: Automatic Mode

var(*LIST).STD.FAILBACK-MODE

S

*MANUAL
*AUTOMATIC

*STD

Failover mode set in the Storage Cluster
*MANUAL: Manual mode
*AUTOMATIC: Automatic Mode

var(*LIST).STD.FAILOVER-MODE

S

*MANUAL
*AUTOMATIC

*STD

Reason for error in the Storage Cluster
*UNKNOWN: Unknown error
*NONE: No error
*GROUP-DISCONNECTED: Device path not available
*WRONG-VERSION: Device or firmware not suitable for SCO
*GROUP-SETTING-MISSING: Missing setting for device
*GROUP-SETTING-MISMATCH: Data transfer cannot be executed
*CLUSTER-CONTROL-SERVER-DISCONNECTED: Cluster control server not connected

var(*LIST).STD.HALT-FACTOR

S

*UNKNOWN
*NONE
*GROUP-DISCONNECTED
*WRONG-VERSION
*GROUP-SETTING-MISSING
*GROUP-SETTING-MISMATCH
*CLUSTER-CONTROL-SERVER-DISCONNECTED

*STD

Number of BS2000 volumes in the storage cluster

var(*LIST).STD.NUM-OF-BS2-VOL

I

<integer 0..4096>

*STD

Operating status of the Storage Cluster
*NORMAL: Synchronous operation
*DISABLED: Cluster disabled
*INITIALIZED: Cluster initialized but no volumes yet
*MAINTENANCE: Clone sessions are cleared
*FAILED: Synchronization not possible
*FAILED-OVER: Failover executed
*COPYING: Synchronization to secondary storage system in progress
*COPYING BACK: Synchronization to primary storage system in progress
*FAILBACK-READY: Ready for failback
*FAILED-BACK: Failback executed
*UNKNOWN: Network problem

var(*LIST).STD.PHASE

S

*NORMAL
*DISABLED
*INITIALIZED
*MAINTENANCE
*FAILED
*FAILED-OVER
*COPYING
*COPYING-BACK
*FAILBACK-READY
*FAILED-BACK
*UNKNOWN

*STD

Operating status of the primary storage
system
*ACTIVE: Active storage system
*STANDBY: Standby storage system
*NONE: No operating status
*UNKNOWN: Unknown operating status

var(*LIST).STD.PRIMARY-MODE

S

*ACTIVE
*STANDBY
*NONE
*UNKNOWN

*STD

Serial number of the primary storage system

var(*LIST).STD.PRIMARY-SERIAL-NO

S

''
<c-string 3..14>

*STD

Operating status of the secondary storage system
*ACTIVE: Active storage system
*STANDBY: Standby storage system
*NONE: No operating status
*UNKNOWN: Unknown operating status

var(*LIST).STD.SECONDARY-MODE

S

*ACTIVE
*STANDBY
*NONE
*UNKNOWN

*STD

Serial number of the secondary storage system

var(*LIST).STD.SECONDARY-SERIAL-NO

S

''
<c-string 3..14>

*STD

Behavior in case the automatic REC connection from the active to the standby storage system is disconnected.
*WRITE: The write process for the volume in the active storage system is continued. A data inconsistency to the volume in the standby storage system is created.
*READ: The volume in the active storage system is only being used for read processes. Write processes are rejected.

var(*LIST).STD.SPLIT-MODE

S

*WRITE
*READ

*STD

Status of the Storage Cluster
*NORMAL: Normal operation
*DISABLED: Disabled
*HALT: Error in the Storage Cluster, see HALT-FACTOR
*UNKNOWN: Unknown

var(*LIST).STD.STATUS

S

*NORMAL
*DISABLED
*HALT
*UNKNOWN

*STD

Name of the Storage Cluster

var(*LIST).VOLS.CLUSTER-NAME

S

''
<posix_filename 3..16>

*VOLUMES

Using the Continuous Copy function for the volume
*YES: Function is used
*NO: Function is not used

var(*LIST).VOLS.CONTINUOUS-COPY

S

''
<c-string 1..4>

*VOLUMES

Synchronization progress of the volumes in the Storage Cluster (in percent)

var(*LIST).VOLS.PRECENT-SYNCHED

S

<integer 0..100>

*VOLUMES

Internal number of the volume in the primary storage system

var(*LIST).VOLS.PRIM-LOGIC-VOL

S

''
<c-string 1..5>

*VOLUMES

Remote copy status of the volumes in the Storage Cluster
*ACTIVE: Remote copy mode active
*IN-HOLD: Remote copy mode interrupted (/HOLD-REMOTE-COPY)

*FAILED-OVER: Remote copy session interrupted (/FAILOVER-STORAGE-CLUSTER)

*ERROR: Remote copy mode interrupted after an error
*BROKEN: Unrecoverable error after failure

var(*LIST).VOLS.REM-COPY-STA

S

*ACTIVE
*IN-HOLD
*FAILED-OVER
*ERROR
*BROKEN

*VOLUMES

Internal number of the volume in the secondary storage system

var(*LIST).VOLS.SEC-LOGIC-VOL

S

''
<c-string 1..5>

*VOLUMES

Synchronization status of the volumes in the Storage Cluster
*SYNCHRONIZED: Volumes are synchronized
*SYNCHRONIZING: Volumes are being synchronized
*UNKNOWN. Unknown

var(*LIST).VOLS.SYNC-STA

S

*SYNCHRONIZED
*SYNCHRONIZING
*UNKNOWN

*VOLUMES

MN of the BS2000 volume in the Storage Cluster (if configured)

var(*LIST).VOLS.UNIT

S

''
<c-string 1..5>

*VOLUMES

VSN of the BS2000 volume in the Storage Cluster (if readable)

var(*LIST).VOLS.VOL

S

''
<c-string 1..6>

*VOLUMES

Command return codes

(SC2)

SC1

Maincode

Meaning


0

CMD0001

Command executed successfully


1

CMD0202

Syntax error


32

NDE2002

Internal error


64

CMD0087

Function not permitted in the current input mode or with the current task privileges


64

CMD0216

Required privilege not available


64

NDE1601

Storage Cluster not found


64

NDE1802

Error communicating with StorMan server


64

NDE1803

Management Instance not available


64

NDE1807

No storage system found


64

NDE1810

Operating system version not in storage system


64

NDE1814

Storage system’s serial number not found


64

NDE1815

Storage system’s serial number not unique


64

NDE2000

Execution partially successful


64

NDE2001

Command not executed


64

NDE2006

No output information available


130

NDE1082

Memory bottleneck during processing of command