Remote copy mode must be interrupted because the local storage system must remain ready for operation during the test. In order to have consistent data for the test, a synchronization point should be created beforehand. It can also make sense to rename the pubset concerned.
Actions in the local system
Check whether the source and target units are synchronized.
Global check:
SYNCH
field displays100%
/SHOW-REMOTE-COPY-STATUS UNIT=F300,INFORMATION=*SUMMARY % --------------------------------------------------------------------------- % SRC TAR VOLUME!REMOTE-COPY TARGET!LAST-STA-CHNG!LINK !SYNC!SRC!CON!CAS % UNIT UNIT !STATE MODE ACCESS!DDDD.HH:MM:SS! ! !-RA!R-C!R-C % =========================================================================== % F300 F886 ET01.0!ACTIVE SYNC BY-SRC! - !AVAIL.!100%! - !NO ! -
Interrupt remote copy mode (optionally with integrated pubset renaming), e.g.
/HOLD-REMOTE-COPY.
/SHOW-REMOTE-COPY-STATUS UNIT=F300,INFORMATION=*SUMMARY % --------------------------------------------------------------------------- % SRC TAR VOLUME!REMOTE-COPY TARGET!LAST-STA-CHNG!LINK !SYNC!SRC!CON!CAS % UNIT UNIT !STATE MODE ACCESS!DDDD.HH:MM:SS! ! !-RA!R-C!R-C % =========================================================================== % F300 F886 ET01.0!IN-HOLD SYNC DIRECT! - !AVAIL.! 99%! - !NO ! -
Actions on the standby system
None
The target unit is activated automatically by /HOLD-REMOTE-COPY
, i.e. the target units are in the READY
status.