Summary of failure scenarios

&pagelevel(4)&pagelevel

Failure

Reported
with

Operation
interrupted?

Impact

Response
(measure)

Data inconsistency
on later switch to
targets?

source unit

NDE0020

No

Local redundancy

Customer support

No

target unit

NDE0020

No

Remote redundancy

Customer support

No

Single remote link

NDE0019

No

Write performance

Customer support

No

Last remote link

NDE0019

No

-

Customer support
Note
inconsistency

Yes

Storage system with source units

PGER message

Yes


Measure A

Possible 1

Local system

Yes

-

Restart

No

Complete failure 2

Yes


Measure A

Possible 1

Failback to local storage system

Yes


Measure B


1 Data inconsistency on later switching to the targets is possible in the event of preceding faults on the remote links or target units.

2 Failure of the local storage system with source units and failure of the local system.

Failure recovery measures

Measure

Description

Condition

Action

Command                                        

A

Switch to target unit, local system affected


Start standby host, attach target units

/ATTACH-DEVICE

Source and target units were synchronized

Make target units available

/HOLD-REMOTE-COPY

Source and target units were not synchronized, inconsistencies acceptable (or reset to last synchronization point)


/HOLD-REMOTE-COPY ...,
  FORCE=YES

B

Failback to the local storage system, operation on standby host


Terminate use of target units

/EXPORT-PUBSET


Disable all channels and remote links on local storage system

(Service)


Start local storage system

(Service)

Local storage system OK
(Service will check)

Attach and enable remote links

(Service)


reconstruct source units from target units

/RESUME-REMOTE-COPY
  RESTORE=*TO-SOURCE

or in single steps

Comparison OK / automatic synchronization begun?

Attach channels

(Service)


Start local system