Performs a manual failback for the specified storage cluster from the secondary storage system back to the primary storage system.
Requirement: After a failover, the primary storage system is available again and the internal resynchronization is completed.
The command is always sent to the primary storage system.
Syntax
|
Parameters
–cluster clustername
Selects the SCO group (storage cluster group) for the failback by the specified name.
Return codes
Error Code | Name | Error Type |
0 |
| Function successful. |
2 |
| Function only partly completed. |
3 |
| Version not supported. |
7 |
| Specified parameters invalid. |
13 |
| Error in StorMan communication between client and server |
16 |
| Unexpected error in function. |
18 |
| Matching object could not be provided. |
21 |
| StorMan SubCode |
22 |
| Provider or database not available |
36 |
| User / password for StorMan not valid |
37 |
| Provider returned an error. StorMan SubCode |
Error subcodes of STORMAN_SUB_SCO_ADD_INFO
:
Subcode | Error Type |
0 | Success |
1 | Not supported |
2 | Unknown |
3 | Timeout |
4 | Failed |
5 | Invalid parameter |
32768 | No license found |
32768 | Invalid TFO (Transparent Failover) group phase |
32768 | No FTV volume type in TFO group |
32768 | TFO group status is inconsistent in the primary storage |
32768 | TFO group status is inconsistent in the secondary storage |
32768 | Invalid TFO group activation specified for the secondary storage (failover) |
32768 | Invalid TFO group activation specified for the secondary storage (failback) |
32768 | REC paths are disabled |
32768 | Invalid TFO group condition |
Example
storcluster –failback –cluster DX500_1-DX500_2