The database operating values of the configuration EXAMPLE are to be monitored. The output mask is to contain status details. The first output device is to be a printer. The interrogation frequency for the printer is to be 60 seconds. The second output device is to be a data display terminal.
The interrogation cycle for the data display terminal is to be 30 seconds. The monitor is to terminate itself after 30 minutes.
/SET-JV-LINK LINK-NAME=VERS,JV-NAME=JV.MANUAL.VERSION
 /SELECT-PRODUCT-VERSION PRODUCT-NAME=UDS-SQL,VERSION=&(*VERS),SCOPE=*TASK
 /START-UDS-MONITOR
 ...
 %  UDS0501 UDSMON ENTER START PARAMETER OR 'HELP‘ (MO81446,13:25:51/66B2) *CONFNAME=BEISPIEL %  UDS0501 UDSMON ENTER START PARAMETER OR ‚HELP‘ (MO81446,13:26:09/66B2)
 *MASK=S %  UDS0501 UDSMON ENTER START PARAMETER OR ‚HELP‘ (MO81446,13:26:21/66B2)
 *MEDIUM=L,60 %  UDS0501 UDSMON ENTER START PARAMETER OR ‚HELP‘ (MO81446,13:26:35/66B2)
 *MEDIUM=T,30 %  UDS0501 UDSMON ENTER START PARAMETER OR ‚HELP‘ (MO81446,13:26:49/66B2)
 *RUNTIME=1800 %  UDS0501 UDSMON ENTER START PARAMETER OR ‚HELP‘ (MO81446,13:27:03/66B2)
 *START
  |