IOGEN logs

&pagelevel(5)&pagelevel

IOGEN generates two logs.

The IOGEN log is written to SYSLST. It contains the following information:

  • List of the input statements. All statements that are read in are logged.

  • IOCF generation lists
    The I/O configuration generated is logged in three tables:

    • The “Physical Channel Listing” contains, for each channel, the generation data and the number of connected controllers and devices.

    • The “Physical Controller Listing” contains, for each controller, the generation data, the number of connected devices and the channel ports with their connection data.

    • The “Physical Device Listing” contains, for each device, the generation data and the controller ports with their connection data.

The IOCGEN log contains detailed information on the I/O units generated.

  • The device table contains – sorted according to the CMPG (in order of ascending CMPG numbers) – generation information on all the devices assigned to the CMPG (in order of ascending subchannel numbers).

  • Additional information for each controller is output in the controller table.

Output of the IOCGEN log can be controlled using the PROT operand of the CPGOPT statement, see "CPGOPT - Define generation options for IOGEN".