BCOUT: Close down route

&pagelevel(4)&pagelevel

If the route to be closed down leads to a router then, if required, the ARP function must be deactivated separately with the MODIFY-ROUTE-ATTRIBUTES command.

BCOUT for routes                                                                 

ROUTE = <rout-name 1 .. 8>

,TYPE = QUICK / NORMAL, ...


NORMAL, ...



|


W = YES / NO

ROUTE=<rout-name 1..8>
Name of the route

TYPE=...
Specifies the type of connection shutdown.

TYPE=QUICK
Connection shutdown occurs in the network.

TYPE=NORMAL, ...
A connection shutdown occurs in the network.

W=...
This operand displays whether or not a warning about the termination of the application is displayed.

W=NO
No warning is displayed.
This option must only be used in “emergencies”, since the relevant applications have no opportunity to terminate under control.

W=YES
A warning is displayed.

Command logging

For reasons of compatibility, the processing acknowledgment is supplied in news BCA0763 if it is positive and in news BCA0762 if it is negative, followed by the message NBR0740. In addition, for positive acknowledgments, the messages BCA0853 and BCA0626 may also appear.
A description of the error messages that may be issued during command processing is provided in the table below. 

Command return codes

(SC2)      SC1

Maincode

Meaning

   0        0

CMD0001

Command successfully processed

   2        0

BCA0627

Shutdown aborted

   2        0

BCA085C

BCOUT has already been entered, command is ignored

   0        1

BCA0768

Syntax error in command

   0       64

BCA07A0

Route is unknown

   0      128

BCA0814

BCAM is being terminated abnormally

   0      128

BCA0816

BCAM is terminating

   0      130

BCA0766

BCAM is not active