BCSHOW |
SHOW = list-poss (4): BCAM / LIMITS / TIMES / SERVER-PORTS ,MAXMSG# = <integer 1 .. 2147483647> |
SHOW=...
Using SHOW, you specify the additional information for display.
The values can also be specified as a list (list-poss).
SHOW=BCAM
BCAM values are displayed.
The information is displayed with console message BCA08F1.
SHOW=LIMITS
Information is displayed about global limit values.
The information is displayed with console message BCA08F8.
SHOW=TIMES
Information is displayed about global timer values.
The information is displayed with console message BCA08F7.
SHOW=SERVER-PORTS
Information is displayed about server ports.
The information is displayed with console message BCA08F9.
MAXMSG#=...
Number of messages to be output for this command
MAXMSG#= *none
By default 50 messages may be output to SYSOUT and 10 displayed on the console.
MAXMSG#=<integer 1 .. 2147483647>
Number of messages which may be output for this command.
The number of messages issued can be exceeded when information is output because of the restricted output length of a message.
Multiple messages are frequently output for BCAM objects. Within BCAM these messages are counted as just one message.
In some cases the message BCA0765 is also issued in order to facilitate the assignment of the output information for the specified command.
Command logging
For reasons of compatibility, the processing acknowledgment is supplied in news BCA0763 if it is positive and in news BCA0762 if it is negative, followed by the message NBR0740. In addition, for positive acknowledgments, the messages BCA08F8, BCA08F7 and BCA08F6 may also appear.
A description of the error messages that may be issued during command processing is provided in the table below.
Command return codes
(SC2) | Maincode | Meaning |
| CMD0001 | Command successfully processed |
| BCA0768 | Syntax error in command |
| BCA0814 | BCAM is being terminated abnormally |
| BCA0816 | BCAM is terminating |
| BCA0766 | BCAM is not active |