This statement is used to select the reports to be output.
Format
Operation | Operands |
|
|
Operands
STD | Selects the following reports:
for output in the same order as shown above. This operand must be specified only if the default value has been changed and is to be reactivated. |
ALL | All reports are output. If a monitoring program has not been activated or is not supplying any data at the moment, an appropriate message is output. |
| Updates the list of reports to be output. “report-type” designates the output reports, the identifiers of which are as follows: |
Report ID | Guaranteed abbreviation | Report name |
ACF | ACF | |
ACTIVITY | A, ACT | ACTIVITY |
BCAM | BCAM CONNECTION | |
BCAM_MEMORY | BCAMM | BCAM MEMORY |
CATEGORY | CAT | CATEGORY |
CATQ | CATEGORY QUEUE | |
CATW | CATEGORY WSET | |
CHANNEL | C, CHA | CHANNEL |
CMS | CMS | |
CPU | CPU | |
DAB | DAB | |
DEVICE_DISK | D, DDISK | DEVICE DISK |
DEVICE_TAPE | DTP | DEVICE TAPE |
DEVICE_TD | DTD | DEVICE TD |
DISK_FILE | DFILE | DISK FILE 1 |
DLM | DLM | |
FILE | F, FIL | FILE 2 |
GLOBAL | G | GLOBAL |
ISAM | ISAM 2 | |
ISAM_FILE | ISAM FILE | |
MEMORY | M, MEM | MEMORY |
MSCF | MSCF | |
NSM | NSM | |
OPENFT | OFT | OPENFT |
PCS | PCS | |
PERIODIC | PER | PERIODIC TASK 1 |
PFA | PFA | |
POSIX | POS | POSIX |
PUBSET | PUB | PUBSET |
RESPONSE | R, RES | RESPONSETIME |
SESAM_SQL | SESAM | SESAM SQL |
SHARED_PUBSET | SHA | SHARED PUBSET |
SVC | SVC | |
TCP_IP | TCP | TCP/IP |
TLM | TLM | |
UDS_SQL | UDS | UDS SQL |
UTM | UTM | |
VM | VM2000 | |
VM_CPU_POOL | VMCP | VM CPU Pool |
VM_GROUP | VMG | VM GROUP |
1 For nonprivileged users, the report only shows them the tasks or files of their own user IDs.
2 For nonprivileged users, only the user-specific reports are output with the monitoring objects of the user.
The user can specify both an individual report identifier with or without prefix and multiple report identifiers (with prefix) one after the other.
The sign preceding the first report type of a line is not mandatory. If omitted, the newly specified report types of this line completely replace the ones previously set.
If the first report type of a line is specified using a prefix, the reports specified in this line are added to (+) or removed from (-) the previous ones.
All further reports of an input line must be prefixed by a sign.
Example 1
REPORT +DAB+CMS
The reports for DAB and CMS are added to the reports already activated.
Example 2
REPORT ALL-DAB
All existing reports are activated, with the exception of the DAB report.