Loading...
Select Version
The device determines the speed of the fans autonomously. The speed cannot be set from the outside. The table below shows the temperature threshold values which result in the fan speed increasing.
By default the threshold value for a warning is 10 degrees Celsius lower than the critical threshold value. As soon as the temperature exceeds the high-limit temperature threshold (TB), the fan operates at maximum speed. When a lower threshold value is fallen below, the fan speed is reduced.
Model | Low-limit temperature | High-limit temperature TB | Critical (shutdown) temperature |
IXC 6450-24 | 66 | 71 | 83 |
IXC 6450-48 | 64 | 69 | 76 |
Table 6: Temperature threshold values