----- PROGRAM LOAD FRAME: DETAIL-1 ----- E90L01G -LOAD FUNCTION- -IPL DEVICE- ==> ==> 2 *1 START AUTO *1 PRESET GROUP ------------------+ *2 START FAST >*2 CURRENT GROUP --------+ | *3 START DIAL *3 UNIT ADDRESS -+ + + *4 START A108 A108 A108 *5 SYSTEM DUMP XXXX XXXX *6 LOAD CLEAR -----+ XXXX XXXX *7 LOAD NON CLEAR -+ XXXX XXXX | +MT CONTROL- --- DETAIL-2 STATUS -- PARMS=> 1 ==> 1 VM MODE : AVM/EX >*1 NL EXA MODE : ENABLE *2 SL IPL EXEC : ENABLE *3 NL-REWIND *4 SL-REWIND *ENTER EXECUTE *PF3 GO TO BASIC FRAME *PF9 GO TO DETAIL-2 CL-0 CPU-0 CHP-0 RUN RA []-[]00
By making entries in this frame and pressing the ENTER key you can control the execution of an IPL.
Before completing this frame, check whether the correct firmware for operating Native BS2000 or VM2000 has been loaded by the SVP. Information on this is provided in the DETAIL-2 STATUS field.
DETAIL-2 STATUS | In this position the current settings of the PROGRAM LOAD FRAME: DETAIL-2 are displayed. VM MODE shows the loaded firmware: | |
NATIVE | for BS2000 operation | |
AVM/EX | for VM2000 |
If the setting is not correct, click on PF9 to correct the entry in PROGRAM LOAD FRAME: DETAIL-2. After you have made the correction and clicked on PF9, the setting is stored and you are returned to this frame (see "(LD) PROGRAM LOAD FRAME: DETAIL-2").
If the setting is correct, complete this frame and execute the IPL.
LOAD FUNCTION ==> | The following function is selected after the corresponding number has been entered: |
1 | START AUTO | executes IPL: automatic startup |
2 | START FAST | executes IPL: fast startup |
3 | START DIAL | executes IPL: dialog startup |
4 | START | not used |
5 | SYSTEM DUMP | executes SLED |
6 | LOAD CLEAR | clears main memory before IPL |
7 | LOAD NON CLEAR | does not clear main memory before IPL |
Functions 6 or 7 must be used for an IPL from a real or emulated tape device. In addition, function 3 must be selected at MT CONTROL (see "(LD) PROGRAM LOAD FRAME: DETAIL-1").
IPL DEVICE ==> | By entering the corresponding number in this field you can specify from which device group an IPL is to be executed. |
1 | PRESET GROUP | The first device address in this column is the device from which an IPL is to be executed. The order and number were specified previously in (AU5) AUXILIARY FRAME: LOAD PRESET-1. |
2 | CURRENT GROUP | The first device address in this column is the device from which the last IPL was executed. |
3 | UNIT ADDRESS | A new device address from which the operating system is to be loaded can be entered here. If the IPL is terminated normally, this device address is put in the first position in the CURRENT GROUP. |
PARMS => | A maximum of 8 characters can be entered in this field. Their position and meaning are listed below: |
Position 1 | 'BLANK' | loading BS2000 |
Position 2 - 5 | mn | The mnemonic pair of an SKP console can be entered here if the standard consoles with the mnemonic pairs C2C3 and C4C5 are not available for the IPL. |
Position 6 - 8 | not used |
MT CONTROL ==> | IPL from tape: |
1 | NL | from current tape position |
2 | SL | skip label then load |
3 | NL-REWIND | rewind then load |
4 | SL-REWIND | rewind, skip label then load |
Function 3 must be selected for an IPL of a real or emulated tape device.
Frame-specific function
ENTER | Executes IPL / SYSTEM DUMP After making your entries in the mask and pressing the ENTER key, the following prompt will appear: *********************************** * * * ARE YOU SURE ? (ENTER Y OR N) N * * * *********************************** CAUTION! The IPL must not be executed during system operation! If this instruction is not heeded, BS2000 will be aborted!
| ||
RETURN | Swap to PROGRAM LOAD FRAME: BASIC (see "(LD) PROGRAM LOAD FRAME: BASIC") | ||
PF9 | Swap to PROGRAM LOAD FRAME: DETAIL-2 (see next page). |