(LD) PROGRAM LOAD FRAME: DETAIL-2

                  ----- PROGRAM LOAD FRAME: DETAIL-2 -----      E90L01G
-VM MODE-                               -IPL EXECUTION-
  ==> 2                                    ==> 1
  *1 NATIVE                               >*1 ENABLE
 >*2 AVM/EX                                *2 DISABLE
 








                                              *ENTER  EXECUTE
                                              *PF3    GO TO BASIC FRAME
                                              *PF9    GO TO DETAIL-1
 
              CL-0            CPU-0 CHP-0          RUN 
RA                                                               []-[]00

Figure 9: PROGRAM LOAD FRAME: DETAIL-2 screen


By making an entry in this frame and pressing the ENTER key, you set the operating mode.

VM MODE ==> 

Selection of the firmware to be loaded from SVP

1

NATIVE

for BS2000 operation

2

AVM/EX

for VM2000

IPL EXECUTION ==>

IPL execution

1

ENABLE

executes IPL

2

DISABLE

does not execute IPL


If there are changes to the VM MODE and IPL EXECUTION ==> 2, only the other firmware is loaded and no IPL is executed.


Frame-specific functions

ENTER

 Sets operating mode.

>

After selecting the firmware to be loaded in the VM MODE ==> field and entering 2 in the IPL EXECUTION ==> field, press the ENTER key.

The following prompt appears on the screen:

***********************************
*                                 *
* ARE YOU SURE ? (ENTER Y OR N) N *
*                                 *
***********************************

CAUTION!

The operating mode must not be reset during system operation! If this instruction is not heeded, BS2000 will be aborted!

>

Press the Y key to reload the firmware, or the N key to cancel the procedure. Confirm your entry with the ENTER key.

>

After reloading the firmware, click on the PF9 key to carry out IPL in PROGRAM LOAD FRAME: DETAIL-1. 

RETURN

Swap to PROGRAM LOAD FRAME: BASIC (see "(LD) PROGRAM LOAD FRAME: BASIC")

PF9

Swap to PROGRAM LOAD FRAME: DETAIL-1 (see "(LD) PROGRAM LOAD FRAME: DETAIL-1") without saving the changes you have made.