(AU5) AUXILIARY FRAME: LOAD PRESET1

&pagelevel(5)&pagelevel
             ----- AUXILIARY FRAME: LOAD PRESET1 -----       E90L01G
-START MODE-             -IPL DEVICE-
 ==> 1 
 >1 START AUTO              1 PRESET GROUP -----------------+
 *2 START FAST              2 CURRENT GROUP --------+       |
 *3 START DIAL              3 UNIT ADDRESS -+       +       +
 *4 START                                   A108    A108    A108
                                                    XXXX    XXXX
                                                    XXXX    XXXX
                                                    XXXX    XXXX
                                             
                                                           -POWER ON IPL-
                                                             ==> 2
                                                             *1 ENABLE
                                                             >2 DISABLE
-INITIAL FRAME-
 ==> 2
 *1 LOAD FRAME(BASIC)                      *PF12  CATALOG
 >2 LOAD FRAME(DETAIL)                     *PF9   GO TO LOAD PRESET-2
          CL-0        CPU-0 CHP-0           RUN
 RA                                                       []-[]00

Figure 21: AUXILIARY FRAME: LOAD PRESET1 screen


You can predefine the execution of an IPL by making an entry in this frame and clicking on PF12.

START MODE ==>

Predefine the loading mode by entering the appropriate number and comment for the BS2000 loading mode:

1

START AUTO

for automatic startup

2

START FAST

for fast startup

3

START DIAL

for dialog startup

4

START

not used

IPL DEVICE

Entries in this field specify from which device an IPL should be executed.

1

PRESET GROUP

Up to four unit addresses can be entered in the input field for PRESET GROUP. The operating system is loaded from the first device (IPL). In the case of an error, the IPL is executed by the next device listed.

POWER ON IPL ==>

Here you determine the behavior of the SVP after switching on.

1

ENABLE

automatically executes IPL after IMPL

2

DISABLE

does not execute IPL, i.e. IPL must be triggered manually using PROGRAM LOAD FRAME: BASIC or PROGRAM LOAD FRAME: DETAIL-1

INITIAL FRAME ==>

Here you can set the display form of the PROGRAM LOAD FRAME.

1

LOAD FRAME (BASIC)

PROGRAM LOAD FRAME: BASIC (see "(LD) PROGRAM LOAD FRAME: BASIC")

2

LOAD FRAME (DETAIL)

PROGRAM LOAD FRAME: DETAIL-1 (see "(LD) PROGRAM LOAD FRAME: DETAIL-1" )


Frame-specific functions

PF12

Storing settings

PF9

switches to the LOAD PRESET2 screen

                  ----- AUXILIARY FRAME: LOAD PRESET2 -----   E90L01G
-VM MODE-
 ==> 2
 *1 NATIVE
 >2 AVM/EX






-START IPL NO-
 ==> 1
 >1 FIX(1)
 *2 CURRENT
 


                                              *PF12   CATALOG
                                              *PF9    GO TO LOAD PRESET-1
            CL-0       CPU-0 CHP-0             RUN
              0
 RA                                                           []-[]00

Figure 22: AUXILIARY FRAME: LOAD PRESET2 screen


You can set the operation mode by making an entry in this frame and clicking on PF12.

VM MODE ==>

Selection of the firmware to be loaded from SVP

1

NATIVE

for BS2000 operation

2

AVM/EX

for VM2000

START IPL NO ==>

Selection of the IPL Start Mode number

1

FIX(1)

Start Mode number 1 (automatic start)

2

CURRENT

not used on the Server Unit


Frame-specific functions

PF12

Storing settings

PF9

switches to the LOAD PRESET1 screen