Your Browser is not longer supported

Please use Google Chrome, Mozilla Firefox or Microsoft Edge to view the page correctly
Loading...

{{viewport.spaceProperty.prod}}

Restarting the monitor system via SVP (SU /390)

&pagelevel(4)&pagelevel
On SU x86, the monitor system can be restarted via the SE manager or using the SVP functions of the KVP console which is assigned to the monitor system (see manual “Operation and Administration” [19]).

Use of the restart facility in the SVP (on SU /390) requires the same conditions as an automatic restart of the monitor system.
Exception: the restart option does not need to be set.

If the following problems occur in the monitor system, and /SHUTDOWN can no longer be entered, the monitor system can be restarted using SVP:

  • Problems that do not result in abnormal system termination (“hung” system in the monitor system, UCON BUSY, no input possible)

  • SETS without the Restart option (VMS0018)


Initialize restart

To restart the monitor system using SVP, in the main menu of the SE Manager (SU /390 selected) the SVP console tab must be selected, the SVP console opened and in the MODE SELECTION FRAME screen the RESTART function activated.


Restart procedure

The restart of the monitor system then proceeds in the same way as an automatic restart after SETS in the monitor system (with SLED), see "Automatic restart after SETS in the monitor system".