The View menu contains the following option:
Filter ...
Controls whether installation units, supply units or packages are displayed in the body.
1. View: Filter
You decide if installation units, supply units, correction deliveries or registered deliveries (packages) of the currently open SCI are to be displayed in the work area with the option 1 (Filter) of the Select menu.
Enter the desired setting using the “Filter” dialog box:
File Edit Show View Options .......................................... ----------------------------------- : Filter : : -------------------------------------- : ----------------------------------- : 3 1. Installation units : nits 1 through 13 of 168 : 2. Supply units ... : selection More: + : 3. Supply units for Request Delivery : on Corr state : 4. Packages (deliveries) : 0 A00 : : 5 A00 : F12=Cancel : 0 A00 :........................................: 0 A00 ANITA 21.0 A00 APACHE 02.4 A00 ARCHIVE 12.0 C00 ASE 21.0 A00 ASSEMBH 01.4 A10 ASSEMBH-GEN 01.4 A10 ASSTRAN 05.4 A00 ASTI 21.0 A00 ATS 05.3 A20 ------------------------------------------------------------------------------ Command ==> F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 50: Initial selection of installation units and supply units
Options in the dialog box:
Installation units
Supply units
Supply units for Request Delivery
Packages (deliveries)
Selecting the installation units
Default: installation units are to be displayed in the work area. The following screen is output:
File Edit Show View Options ------------------------------------------------------------------------------ IMON: SCI: :I29A:$TSOS.SYS.IMON.SCI ------------------------------------------------------------------------------ Units 1 through 13 of 168 Installation units selection More: + Unit name Version Corr state ACS 21.0 A00 AID 03.5 A00 AIDSYS 21.0 A00 AIDSYSA 21.0 A00 ANITA 21.0 A00 APACHE 02.4 A00 ARCHIVE 12.0 C00 ASE 21.0 A00 ASSEMBH 01.4 A10 ASSEMBH-GEN 01.4 A10 ASSTRAN 05.4 A00 ASTI 21.0 A00 ATS 05.3 A20 ------------------------------------------------------------------------------ Command ==> F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 51: Selection of installation units
Note
Installation units that could not be allocated (no SYSSII file) are indicated by a hash character (#).
Dialog box for selecting the supply units
View supply units in the body. Another dialog box appears in which you can specify supply units with specific package names and user codes and specific characteristics, such as “last installation”, “activable” or a particular installation status that you want to view.
File Edit Show View Options .......................................... ----------------------------------- : Filter : : ...................................................................... ----- : : Filter supply units : 68 : : ------------------------------------------------------------------ : + : : Package name: 1 1. All 2. Other : : : Name: : : : User code...: 1 1. All 2. Other : : : Name: : : : : : Customer approved....: 1 1. All 2. Yes 3. No : : Last installation....: 1 1. All 2. Last : : Activable............: 1 1. All 2. Yes 3. No : : : : Installation Status: / Installed / Being installed : : / Parked / In Library : : / On SOLIS2 Volume / On Local Volume : : / Being deinstalled / Partially installed : : / Others : : : - : F1=Help F12=Cancel : ----- C :....................................................................: F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 52: Initial selection of supply units
Package name | |
Display all supply units or only the supply units of a certain delivery (selection criterion: Package name). | |
1 (All) | |
Default: Display all supply units. | |
2 (Other) | |
Display only the supply units of the delivery with the package name specified in the “Name” field. | |
Name | |
The package name. | |
User code | |
Display all supply units or only the supply units of a certain delivery (selection criterion: User code). | |
1 (All) | |
Default: Display all supply units. | |
2 (Other) | |
Display only the supply units from the delivery or the deliveries with the user code specified in the “Name” field. | |
Name | |
User code. | |
Customer-Approved | |
States whether only the supply units with a customer approval ID are to be displayed. | |
1 (All) | |
Default: all supply units are displayed. | |
2 (Yes) | |
Only the supply units with a customer approval ID are displayed. | |
3 (No) | |
Only the supply units without a customer approval ID are displayed. | |
Last installation | |
States whether the last installed supply unit is to be displayed. | |
1 (All) | |
Default: all supply units are displayed. | |
2 (Last) | |
Only the last installed versions of supply units are displayed. | |
Activable | |
States whether the supply units which are activable in the current session should be displayed. | |
1 (All) | |
Default: all supply units are displayed. | |
2 (Yes) | |
Only supply units that can still be activated are displayed. | |
3 (No) | |
Only supply units that cannot be activated are displayed. | |
Installation Status | |
Selects the supply units, which are in one of the indicated installation status (OR-gate). On the meaning of the installation status also see "Installation state of supply units" (Fetching information from the SCI ). Initially all conditions are marked with “/”, i.e. selection is independent of this selection criterion. |
Select supply units from the SCI
When you open an SCI and set the output of supply units using the Filter option in the View menu, the supply units that are registered in the SCI are displayed in the selection window.
You can now select supply units for further processing from this list.
File Edit Show View Options ------------------------------------------------------------------------------ IMON: SCI: :I29A:$TSOS.SYS.IMON.SCI ------------------------------------------------------------------------------ Units 1 through 13 of 168 SU selection More: + Unit name Vers Corr Package name User code Inst. Status CAP Act ACS 21.0 A00 <package-name> SOL2P Installed N Y AID 03.5 A00 <package-name> SOL2P Installed N Y AIDSYS 21.0 A00 <package-name> SOL2P Installed N Y AIDSYSA 21.0 A00 <package-name> SOL2P Installed N Y ANITA 21.0 A00 <package-name> SOL2P Installed N Y APACHE 02.4 A00 <package-name> SOL2P Installed N Y ARCHIVE 12.0 C00 <package-name> SOL2P Installed N Y ASE 21.0 A00 <package-name> SOL2P Installed N Y ASSEMBH 01.4 A10 <package-name> SOL2P Installed N Y ASSEMBH-GEN 01.4 A10 <package-name> SOL2P Installed N Y ASSTRAN 05.4 A00 <package-name> SOL2P Installed N Y ASTI 21.0 A00 <package-name> SOL2P Installed N Y ATS 05.3 A20 <package-name> SOL2P Installed N Y ------------------------------------------------------------------------------ Command ==> F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 53: Select supply units in the selection window
Select the supply units by entering any character in front of the desired supply unit and confirm your selection by pressing [DUE].
Select correction deliveries (supply units)
All supply units with their most recently installed main version are to be displayed in the work area.
The most recently installed main version is displayed in the work area of each supply unit registered in the SCI after a SCI has been opened and output of Supply units for Request Delivery has been set using the Filter option of the View menu (otherwise as in figure 53).
Supply units can now be selected in the work area for further processing. The Request correction delivery option of the Edit menu is now available for the selected supply units (see "Edit menu ").
Selecting the deliveries
The deliveries registered in the SCI are to be displayed with their package names in the work area.
In a further dialog box, the display can be limited to deliveries which have been registered in the SCI within a specific time period, or which were produced within a specific time period, or which contain supply units in a specific installation status:
File Edit Show View Options ................................ --------------------------------------------- : Filter : IMON.SCI : ......................................................................... -- : : Filter packages : : : --------------------------------------------------------------------- : - : : Registration Date (in SCI): : : : From: 1 1. Any 2. Date : : : (jjjj-mm-tt): : : : To: 1 1. Any 2. Date : : : (jjjj-mm-tt): : : Generation Date (package name): : : From: 1 1. Any 2. Package : : (JJMMMnnnnn): : : To: 1 1. Any 2. Package : : (JJMMMnnnnn): : : : : Contained SU Status: 1 1. Any 2. All installed : : 3. Partially installed 4. Nothing installed : : : : F1=Help F12=Cancel : - :.......................................................................: -- Command ==> F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 54: Limitation to registered deliveries with specific criteria
Registration Date (in SCI) | |
Selects deliveries which have been entered in the SCI within the stated time interval. | |
From | |
Selects deliveries whose creation date | |
1 (Any) | |
Default: The time interval has no lower limit. | |
2 (Date) | |
The date stated in the following field sets a lower limit for the time interval. | |
To | |
Selects deliveries whose registration date | |
1 (Any) | |
Default: The time interval has no upper limit. | |
2 (Date) | |
The date stated in the following field sets an upper limit for the time interval. | |
Generation Date (package name) | |
Selects deliveries which have been produced within the stated interval. | |
From | |
Selects deliveries whose generation date | |
1 (Any) | |
Default: The interval has no lower limit. | |
2 (Package) | |
The package name stated in the following field sets a lower limit for the interval. | |
To | |
Selects deliveries whose generation date | |
1 (Any) | |
Default: The interval has no upper limit. | |
2 (Package) | |
The package name stated in the following field sets an upper limit for the interval. | |
Contained SU Status | |
Selects deliveries depending on the installation status of the supply units they contain. | |
1 (Any) | |
Default: The installation status of the contained supply units is not a selection criterion. | |
2 (All installed) | |
Only selects deliveries in which all of the supply units are already installed. | |
3 (Partially installed) | |
Selects deliveries where only part of all the supply units have already been installed. | |
4(Nothing installed) | |
Only selects deliveries in which none of the supply units have yet been installed. |
Select deliveries from the SCI
When you open an SCI and set the output of supply units using the Filter option in the View menu, the deliveries that are registered in the SCI are displayed in the selection window.
You can now select deliveries for further processing from this list.
File Edit Show View Options ------------------------------------------------------------------------------ IMON: SCI: :I29A:$TSOS.SYS.IMON.SCI ------------------------------------------------------------------------------ Package 1 through 3 of 3 Package selection More: Package name User code x <package-name-1> SOL2p <package-name-2> SOL2p <package-name-3> SOL2P *** End of Package selection *** ------------------------------------------------------------------------------ Command ==> F1=Help F3=Exit F5=Previous F6=Next F7=Backward F8=Forward F10=Menu ...
Figure 55: Selection of registered deliveries