----- AUXILIARY FRAME: LOAD PRESET1 ----- E90L01G -START MODE- -IPL DEVICE- ==> 1 >1 START AUTO 1 PRESET GROUP -----------------+ *2 START FAST 2 CURRENT GROUP --------+ | *3 START DIAL 3 UNIT ADDRESS -+ + + *4 START A108 A108 A108 XXXX XXXX XXXX XXXX XXXX XXXX -POWER ON IPL- ==> 2 *1 ENABLE >2 DISABLE -INITIAL FRAME- ==> 2 *1 LOAD FRAME(BASIC) *PF12 CATALOG >2 LOAD FRAME(DETAIL) *PF9 GO TO LOAD PRESET-2 CL-0 CPU-0 CHP-0 RUN RA []-[]00
Figure 21: AUXILIARY FRAME: LOAD PRESET1 screen
You can predefine the execution of an IPL by making an entry in this frame and clicking on PF12.
START MODE ==> | Predefine the loading mode by entering the appropriate number and comment for the BS2000 loading mode: |
1 | START AUTO | for automatic startup |
2 | START FAST | for fast startup |
3 | START DIAL | for dialog startup |
4 | START | not used |
IPL DEVICE | Entries in this field specify from which device an IPL should be executed. |
1 | PRESET GROUP | Up to four unit addresses can be entered in the input field for PRESET GROUP. The operating system is loaded from the first device (IPL). In the case of an error, the IPL is executed by the next device listed. |
POWER ON IPL ==> | Here you determine the behavior of the SVP after switching on. |
1 | ENABLE | automatically executes IPL after IMPL |
2 | DISABLE | does not execute IPL, i.e. IPL must be triggered manually using PROGRAM LOAD FRAME: BASIC or PROGRAM LOAD FRAME: DETAIL-1 |
INITIAL FRAME ==> | Here you can set the display form of the PROGRAM LOAD FRAME. |
1 | LOAD FRAME (BASIC) | PROGRAM LOAD FRAME: BASIC (see "(LD) PROGRAM LOAD FRAME: BASIC") |
2 | LOAD FRAME (DETAIL) | PROGRAM LOAD FRAME: DETAIL-1 (see "(LD) PROGRAM LOAD FRAME: DETAIL-1" ) |
Frame-specific functions
PF12 | Storing settings |
PF9 | switches to the LOAD PRESET2 screen |
----- AUXILIARY FRAME: LOAD PRESET2 ----- E90L01G -VM MODE- ==> 2 *1 NATIVE >2 AVM/EX -START IPL NO- ==> 1 >1 FIX(1) *2 CURRENT *PF12 CATALOG *PF9 GO TO LOAD PRESET-1 CL-0 CPU-0 CHP-0 RUN 0 RA []-[]00
Figure 22: AUXILIARY FRAME: LOAD PRESET2 screen
You can set the operation mode by making an entry in this frame and clicking on PF12.
VM MODE ==> | Selection of the firmware to be loaded from SVP |
1 | NATIVE | for BS2000 operation |
2 | AVM/EX | for VM2000 |
START IPL NO ==> | Selection of the IPL Start Mode number |
1 | FIX(1) | Start Mode number 1 (automatic start) |
2 | CURRENT | not used on the Server Unit |
Frame-specific functions
PF12 | Storing settings |
PF9 | switches to the LOAD PRESET1 screen |