BCOUT: Close down line

&pagelevel(4)&pagelevel

BCOUT for lines                                                                     

LINE = <line-name 1 .. 8>

,ROUTE-SWITCH = NO / YES

LINE=<line-name 1..8>
Name of the line to be deactivated

ROUTE-SWITCH=...
controls the handling of routes with Layer 3 profile IP, IPv6 and INTF which run via the line to be deactivated.

ROUTE-SWITCH=NO
Routes with Layer 3 profile IP, IPv6 and INTF which run via the line to be deactivated are not switched.

ROUTE-SWITCH=YES
Routes with Layer 3 profile IP, IPv6 and INTF which run via the line to be deactivated are switched to the next active line assigned to the same LAN node. If a corresponding line cannot be found, the route is not switched.

Command logging

For reasons of compatibility, the processing acknowledgment is supplied in news BCA0763 if it is positive and in news BCA0762 if it is negative, followed by the message NBR0740. In addition, for positive acknowledgments, the messages BCA0851, BCA0854, BCA085B and BCA0626 may also appear.
A description of the error messages that may be issued during command processing is provided in the table below.

Command return codes

(SC2)      SC1

Maincode

Meaning

   0        0

CMD0001

Command successfully processed

   2        0

BCA0627

Shutdown aborted

   2        0

BCA085C

BCOUT has already been entered; command is ignored

   0        1

BCA0768

Syntax error in command

   0       64

BCA07A2

Line is unknown

   0      128

BCA0814

BCAM is being terminated abnormally

   0      128

BCA0816

BCAM is terminating

   0      128

BCA0766

BCAM is not active